文献速递皮肤肿瘤

面部术后疤痕表皮缝合:可吸收聚乳酸910与尼龙随机对照试验

Photographic assessment of postsurgical facial scars epidermally sutured with rapidly absorbable polyglactin 910 or nylon: A randomized clinical trial.
PubMed 文献 · J Am Acad Dermatol · 2020-06-10

该随机盲法分疤试验纳入105例Mohs显微描记手术后面部伤口患者,半侧用快速可吸收5-0聚乳酸910缝合表皮,另半侧用5-0尼龙缝合。术后6个月两名不知缝合分配的医师通过照片评估疤痕外观,三种量表评分均无显著差异,提示两种缝线在表皮缝合后6个月的面部疤痕照片外观等效。

要点

  • 快速可吸收聚乳酸910与尼龙表皮缝合后6个月面部疤痕照片外观无显著差异。
  • 该结论来自随机盲法分疤试验,纳入105例Mohs术后面部伤口患者。
  • 临床可依据操作便利与患者偏好选择表皮缝线,不必顾虑疤痕外观差异。

核心结论

  • 快速可吸收聚乳酸910与尼龙用于表皮缝合,术后6个月面部疤痕照片外观等效。

研究设计与样本

  • 随机盲法分疤临床试验,纳入105例Mohs显微描记手术后面部伤口患者。
  • 同一修复伤口半侧用快速可吸收5-0聚乳酸910缝合表皮,另半侧用5-0尼龙缝合。

临床怎么用

  • 面部术后表皮缝合可依据操作便利与患者偏好选择快速可吸收聚乳酸910或尼龙,无需顾虑6个月疤痕照片外观差异。

局限性

  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Surgeons use absorbable and nonabsorbable sutures for epidermal wound closure. No large, randomized studies have compared the effect of these suture types on facial scar appearance. OBJECTIVE: To assess postsurgical facial scar appearance using either rapidly absorbable polyglactin 910 or nylon for epidermal closure. METHODS: Randomized, blinded, split-scar clinical trial. A total of 105 patients with facial wounds resulting from Mohs micrographic surgery excisions were randomly assigned for epidermal closure with rapidly absorbable 5-0 polyglactin 910 (Vicryl Rapide) on one half of the repair and 5-0 nylon (Ethilon) on the other half. Two physicians (1 dermatologist and 1 plastic surgeon), unaware of the original suture location, examined photographs of each healed wound at 6 months after surgery and graded the appearance of each half of the scar using the visual analog scale, wound evaluation scale, and Stony Brook Scar Evaluation Scale. RESULTS: At 6 months, there was no significant difference in the combined mean (standard deviation) visual analog scale scores (83.1 [14.2] and 83.0 [13.7]), Stony Brook Scar Evaluation Scale scores (4.3 [0.9] and 4.4 [0.9]), or wound evaluation scale scores (5.3 [1.1] and 5.2 [1.1]) for rapidly absorbable polyglactin 910 versus nylon (P = .72, .57, and .21, respectively). LIMITATIONS: Single institution. CONCLUSIONS: Both rapidly absorbable polyglactin 910 and nylon sutures placed through the epidermis resulted in an equivalent photographic appearance of facial scars at 6 months after surgery.

来源:J Am Acad Dermatol,查看原文。版权归原作者所有。

引用

  1. Moran B, Humphrey S, Seal A, et al. Photographic assessment of postsurgical facial scars epidermally sutured with rapidly absorbable polyglactin 910 or nylon: A randomized clinical trial. J Am Acad Dermatol. 2020. PMID: 32534080. doi:10.1016/j.jaad.2020.06.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。