紫外线摄影在白癜风评估中的图像质量、效度与信度
本研究纳入17例白癜风患者的31处皮损,比较紫外线摄影与常规相机在图像质量及皮损测量上的表现。结果显示紫外线摄影图像质量优良率达100%,且与数字表面测量结合的组内相关系数达0.984,评定者内与评定者间信度分别为0.999和0.998,表明其用于白癜风皮损评估有效且可靠。
要点
- 紫外线摄影图像质量优于常规相机,优良率达100%。
- 紫外线摄影联合数字表面测量评估皮损大小的效度高(ICC=0.984)。
- 评定者内与评定者间信度均极高(ICC分别为0.999和0.998)。
核心结论
- 紫外线摄影用于白癜风皮损评估可提高图像质量,且效度和信度良好。
研究设计与样本
- 纳入17例白癜风患者的31处皮损,分别用紫外线摄影和常规相机成像,并在方格纸和透明片上描记皮损。
- 由白癜风专家和医学实习生对图像质量评分,计算皮损大小的组内相关系数(ICC)以评估效度,并计算同一医生及不同医生间ICC以评估信度。
主要发现
- 紫外线摄影图像质量被评为好或非常好的比例为100%,常规相机为26%。
- 紫外线摄影、常规相机、透明片描记和方格纸描记的皮损大小ICC分别为0.984、0.988和0.983。
- 评定者内ICC为0.999,评定者间ICC为0.998。
关键数值与推荐
- 紫外线摄影图像质量好或非常好的比例为100%(31处皮损,17例患者)。
- 紫外线摄影联合数字表面测量评估皮损大小的ICC为0.984。
- 评定者内ICC为0.999,评定者间ICC为0.998。
临床怎么用
- 在白癜风临床诊疗和研究中,可考虑采用紫外线摄影替代常规相机以提升皮损评估的图像质量和测量可靠性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: For clinical care and research in vitiligo, photographs with the use of ultraviolet (UV) light or Wood's lamp are often made. Conventional cameras are insensitive to UV light. The use of a UV camera (UV photography) might improve image quality and ameliorate the assessment of target lesions in vitiligo. OBJECTIVES: To determine image quality and the validity and reliability of UV photography for the assessment of vitiligo target lesions. METHODS: Images of patients with vitiligo were made with UV photography and a conventional camera, and lesions were drawn on graph paper and transparent sheets. Image quality was scored by vitiligo experts and medical interns. The intraclass correlation coefficients (ICCs) of the lesion size determined with UV photography combined with digital surface measurement and the other techniques were hypothesized to be above 0.6. The ICCs between UV images taken by the same physician and between two different physicians were calculated for determining inter- and intra-reliability. RESULTS: In total, 31 lesions of 17 patients were included. Image quality was assessed as good or very good for 100% and 26% for UV photography and the conventional camera, respectively. ICCs of UV photography and the conventional camera, drawing the lesions on transparent sheets and graph paper, were 0.984, 0.988 and 0.983, respectively, confirming our hypotheses. The ICCs of the intra-rater and inter-rater were 0.999 and 0.998, respectively. CONCLUSIONS: The results of this study indicate that the use of UV photography for the assessment of vitiligo lesions improves image quality and is valid and reliable.
引用
- Uitentuis SE, Heilmann MN, Verdaasdonk RM, et al. Ultraviolet photography in vitiligo: image quality, validity and reliability. J Eur Acad Dermatol Venereol. 2020. PMID: 31994253. doi:10.1111/jdv.16226
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。