BIOCHIP间接免疫荧光皮肤科马赛克在大疱性类天疱疮和天疱疮患者中的评分者间信度
本研究评估BIOCHIP多重间接免疫荧光技术诊断大疱性类天疱疮(BP)、落叶型天疱疮(PF)和寻常型天疱疮(PV)的评分者间信度(IRR)。血清来自BP(n=38)、PF(n=8)、PV(n=23)、疾病对照(n=64)和健康志愿者(n=39),共312张BIOCHIP玻片(1872张照片),由10位皮肤科医生判读。Fleiss Kappa显示各分类一致性为一般至中等,BP180最高(k=0.559)。
要点
- BIOCHIP各检测项目评分者间一致性为一般至中等(k=0.257~0.559)。
- BP180一致性最高(k=0.559),猴食管一致性最低(k=0.257)。
- 判读经验差异和染色模式模糊是结果不一致的主要原因。
核心结论
- BIOCHIP马赛克免疫荧光检测简单省时,可辅助BP、PV和PF的诊断与筛查,但评分者间一致性相对较低。
研究设计与样本
- 研究纳入BP(n=38)、PF(n=8)、PV(n=23)、疾病对照(n=64)和健康志愿者(n=39)的血清,在病程中1-5个时间点采集分析。
- 共312张BIOCHIP玻片(1872张照片),由10位有免疫荧光判读经验的皮肤科医生独立判读,使用Fleiss Kappa评估评分者间信度。
主要发现
- 猴食管一致性一般(k=0.257,P<0.0001),食管荧光模式一致性一般(k=0.357,P<0.0001)。
- Dsg1一致性一般(k=0.390,P<0.0001),BP230一致性一般(k=0.281,P<0.0001)。
- 盐裂皮肤(SSS)一致性中等(k=0.416,P<0.0001),SSS荧光位置一致性中等(k=0.505,P<0.0001)。
- Dsg3一致性中等(k=0.437,P<0.0001),BP180一致性中等(k=0.559,P<0.0001)。
关键数值与推荐
- 各分类的Fleiss Kappa值:猴食管0.257、食管模式0.357、Dsg1 0.390、BP230 0.281、SSS 0.416、SSS荧光位置0.505、Dsg3 0.437、BP180 0.559,所有P<0.0001。
临床怎么用
- BIOCHIP可用于BP、PV和PF的辅助诊断与筛查,但解读时应考虑判读者经验差异和染色模式模糊的影响。
- 建议对判读者进行规范化培训以缩短学习曲线,提高结果一致性。
局限性
- 评分者间一致性相对较低,可能受判读培训水平差异和染色模式模糊影响。
- 研究未评估不同培训水平判读者间的一致性差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The BIOCHIP (Dermatology Mosaic 7; EUROIMMUN, Lubeck, Germany) is a novel multiplex indirect immunofluorescence (IIF) technique used in the serological diagnosis of bullous pemphigoid (BP) and pemphigus. OBJECTIVE: To validate the accuracy and inter-rater reliability (IRR) of the BIOCHIP in the diagnosis of BP, pemphigus foliaceus (PF) and pemphigus vulgaris (PV). METHODS: Sera from patients with BP (n = 38), PF (n = 8), PV (n = 23), control patients (n = 64) and healthy control volunteers (n = 39) were tested. Sera were collected and analysed during the course of the disease at 1-5 different time points. The BIOCHIP was performed for all patients, digital images were captured of each incubated field, and the images were shared with 10 dermatologists experienced in reading IF from around the world to report. There were 312 BIOCHIP slides consisting of 1872 photos in total. All patients were de-identified. Fleiss Kappa was used to estimate the IRR. RESULTS: Fleiss Kappa was computed for each category (Oesophagus, Oesophagus immunofluorescence pattern, Salt-Split Skin (SSS), SSS immunofluorescence location, BP180, BP230, Dsg 1 and Ds3). The inter-rater agreement between the 10 raters varied between fair and moderate for all categories. Those that demonstrated fair concordance included monkey oesophagus (k = 0.257, P < 0.0001), oesophagus pattern (k = 0.357, P < 0.0001), Dsg1 (k = 0.390, P < 0.0001) and BP230 (k = 0.281, P < 0.0001). Moderate agreement was demonstrated for SSS (k = 0.416, P < 0.0001), SSS immunofluorescence location (k = 0.505, P < 0.0001), Dsg3 (k = 0.437, P < 0.0001) and BP180 (k = 0.559, P < 0.0001). CONCLUSION: The BIOCHIP mosaic-based immunofluorescence test is a simple, time and effort saving test that can aid in the diagnosis and screening of BP, PV and PF. However, the level of agreement was relatively low. The authors found the most common causes to be variable levels of training, indicating the presence of a learning curve in the interpretation of the results and ambiguous staining patterns leading to incongruent results.
引用
- Yang A, Xuan RR, Melbourne W, et al. Inter-rater reliability of the BIOCHIP indirect immunofluorescence dermatology mosaic in bullous pemphigoid and pemphigus patients. J Eur Acad Dermatol Venereol. 2019. PMID: 31325388. doi:10.1111/jdv.15817
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。