文献速递皮肤肿瘤

融合离体共聚焦显微镜用于基底细胞癌特征描述:有望改变传统皮肤组织病理学

Basal cell carcinoma characterization using fusion ex vivo confocal microscopy: a promising change in conventional skin histopathology.
PubMed 文献 · Br J Dermatol · 2019-10-27

该前瞻性研究纳入78例Mohs手术切除的基底细胞癌(BCC),评估新型融合离体共聚焦显微镜(同时使用反射与荧光模式)的特征识别效果。大多数BCC特征在双染色融合模式下显示最佳,并新发现树突状和丰满细胞。反射与荧光模式互补,联合评估有益。

要点

  • 融合模式结合反射与荧光,对BCC特征显示优于单一模式。
  • 醋酸联合吖啶橙双染色可增强肿瘤与间质显示且不损伤组织。
  • 荧光模式更利于观察细胞核,反射模式更利于观察细胞质与间质。

核心结论

  • 同时评估反射与荧光模式具有互补效应,融合模式对BCC特征显示更佳。

研究设计与样本

  • 前瞻性纳入2016年9月至2017年6月本科室Mohs手术切除的连续BCC病例,共78例(35例浸润性、25例结节性、12例微结节性、6例浅表性)。
  • 标本行常规Mohs手术后进行离体共聚焦显微镜检查,先使用吖啶橙染色,再使用醋酸和吖啶橙双染色。

主要发现

  • 大多数BCC特征在使用双染色的融合模式下显示更佳。
  • 新发现离体共聚焦显微镜特征:树突状细胞和丰满细胞,此前未见报道。
  • 细胞核特征在荧光共聚焦显微镜(FCM)下显示更佳,而细胞质和周围间质在反射共聚焦显微镜(RCM)下显示更佳。

关键数值与推荐

  • 离体FCM检测BCC的敏感性为88%,特异性为99%(原文背景中已报告)。
  • FCM比传统方法至少快三分之一时间(原文背景中已报告)。

临床怎么用

  • 在Mohs手术中可考虑使用融合离体共聚焦显微镜联合双染色方案辅助评估BCC特征。
  • 根据目标结构选择模式:观察细胞核优先荧光模式,观察细胞质与间质优先反射模式。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ex vivo confocal microscopy (CM) works under two modes, fluorescence and reflectance, allowing the visualization of different structures. Fluorescence CM (FCM) requires a contrast agent and has been used for the analysis of basal cell carcinomas (BCCs) during Mohs surgery. Conversely, reflectance CM (RCM) is mostly used for in vivo diagnosis of equivocal skin tumours. Recently, a new, faster ex vivo confocal microscope has been developed which simultaneously uses both lasers (fusion mode). OBJECTIVES: To describe the BCC features identified on reflectance, fluorescence and fusion modes using this novel device. To determine the best mode to identify characteristic BCC features. To develop a new staining protocol to improve the visualization of BCC under the different modes. METHODS: From September 2016 to June 2017, we prospectively included consecutive BCCs which were excised using Mohs surgery in our department. The lesions were evaluated using ex vivo CM after routine Mohs surgery. The specimens were first stained with acridine orange and then stained using both acetic acid and acridine orange. RESULTS: We included 78 BCCs (35 infiltrative, 25 nodular, 12 micronodular, 6 superficial). Most features were better visualized with the fusion mode using the double staining. We also identified new CM ex vivo features, dendritic and plump cells, which have not been reported previously. CONCLUSIONS: Our results suggest that nuclei characteristics are better visualized in FCM but cytoplasm and surrounding stroma are better visualized in RCM. Thus, the simultaneous evaluation of reflectance and fluorescence seems to be beneficial due to its complementary effect. What's already known about this topic? Ex vivo fluorescent confocal microscopy (FCM) is an imaging technique that allows histopathological analysis of fresh tissue. FCM is faster - at least one-third of the time - than conventional methods. FCM has a sensitivity of 88% and a specificity of 99% in detecting basal cell carcinomas (BCCs). What does this study add? Reflectance and fluorescence modes can be used simultaneously in a new ex vivo CM device. Each mode complements the other, resulting in an increase in the detection of BCC features in fusion mode. A combined staining using acetic acid and acridine orange enhances the visualization of tumour and stroma without damaging the tissue for further histopathological analysis.

来源:Br J Dermatol,查看原文。版权归原作者所有。

引用

  1. Pérez-Anker J, Ribero S, Yélamos O, et al. Basal cell carcinoma characterization using fusion ex vivo confocal microscopy: a promising change in conventional skin histopathology. Br J Dermatol. 2019. PMID: 31220341. doi:10.1111/bjd.18239

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。