指南与共识湿疹皮炎与荨麻疹

建议将甲基丙烯酸羟乙酯纳入英国基线斑贴试验系列

Recommendation to include hydroxyethyl (meth)acrylate in the British baseline patch test series.
指南 / 共识 · Br J Dermatol · 2019-04-21

该研究在2016-2017年于15个英国皮肤科中心将2-HEMA 2%凡士林纳入扩展基线斑贴试验系列,对5920例患者进行检测。结论推荐将2-HEMA纳入英国基线系列,并建议标准化短(甲基)丙烯酸酯系列。

要点

  • 2-HEMA 2%凡士林可有效检测(甲基)丙烯酸酯过敏。
  • 基线系列加入2-HEMA可减少漏诊。
  • 建议标准化短(甲基)丙烯酸酯系列辅助检测。

核心结论

  • 推荐将2-HEMA 2%凡士林加入英国基线斑贴试验系列。
  • 建议采用标准化短(甲基)丙烯酸酯系列以检测多数过敏病例。

研究设计与样本

  • 2016-2017年15个英国皮肤科中心参与,将2-HEMA纳入扩展基线斑贴试验系列。
  • 共5920例患者连续接受基线系列斑贴试验,其中669例还接受了(甲基)丙烯酸酯系列检测。
  • 对有(甲基)丙烯酸酯暴露史或2-HEMA阳性者,选择性检测8种(甲基)丙烯酸酯过敏原。

关键数值与推荐

  • 推荐将2-HEMA 2%凡士林加入英国基线斑贴试验系列。
  • 建议采用标准化短(甲基)丙烯酸酯系列,可能检测多数(甲基)丙烯酸酯过敏病例。

临床怎么用

  • 在基线斑贴试验系列中加入2-HEMA 2%凡士林,以提高(甲基)丙烯酸酯过敏的检出率。
  • 对有(甲基)丙烯酸酯暴露史或2-HEMA阳性者,应使用标准化短(甲基)丙烯酸酯系列进一步检测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: (Meth)acrylates are potent sensitizers and a common cause of allergic contact dermatitis (ACD). The frequency of (meth)acrylate ACD has increased with soaring demand for acrylic nails. A preliminary audit has suggested a significant rate of positive patch tests to (meth)acrylates using aimed testing in patients providing a clear history of exposure. To date, (meth)acrylates have not been routinely tested in the baseline patch test series in the U.K. and Europe. OBJECTIVES: To determine whether inclusion of 2-hydroxyethyl methacrylate (2-HEMA) 2% in petrolatum (pet.) in the baseline series detects cases of treatable (meth)acrylate ACD. METHODS: During 2016-2017, 15 U.K. dermatology centres included 2-HEMA in the extended baseline patch test series. Patients with a history of (meth)acrylate exposure, or who tested positive to 2-HEMA, were selectively tested with a short series of eight (meth)acrylate allergens. RESULTS: In total 5920 patients were consecutively patch tested with the baseline series, of whom 669 were also tested with the (meth)acrylate series. Overall, 102 of 5920 (1·7%) tested positive to 2-HEMA and 140 (2·4%) to at least one (meth)acrylate. Had 2-HEMA been excluded from the baseline series, (meth)acrylate allergy would have been missed in 36 of 5920 (0·6% of all patients). The top (meth)acrylates eliciting a positive reaction were 2-HEMA (n = 102, 1·7%), 2-hydroxypropyl methacrylate (n = 61, 1·0%) and 2-hydroxyethyl acrylate (n = 57, 1·0%). CONCLUSIONS: We recommend that 2-HEMA 2% pet. be added to the British baseline patch test series. We also suggest a standardized short (meth)acrylate series, which is likely to detect most cases of (meth)acrylate allergy.

来源:Br J Dermatol,查看原文。版权归原作者所有。

引用

  1. Rolls S, Chowdhury MM, Cooper S, et al. Recommendation to include hydroxyethyl (meth)acrylate in the British baseline patch test series. Br J Dermatol. 2019. PMID: 30703264. doi:10.1111/bjd.17708

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。