光学相干断层扫描诊断基底细胞癌的效用:一项定量综述
该定量综述从31项研究中提取901个基底细胞癌的肿瘤级数据,评估光学相干断层扫描(OCT)的体内诊断准确性、形态学特征与组织病理诊断的相关性及影响肿瘤深度评估准确性的因素。OCT诊断基底细胞癌的总体灵敏度和特异度分别为89.3%和60.3%,频域OCT最高(分别为93.7%和61.4%)。OCT与组织病理肿瘤深度分级的的一致性为中等(Pearson系数0.48)。
要点
- 频域OCT诊断基底细胞癌的灵敏度93.7%、特异度61.4%,高于时域OCT。
- 小叶型(80.2%,315/393)和高反射瘤周间质(51.7%,203/393)是最常见形态学特征。
- OCT与组织病理肿瘤深度分级的一致性为中等(Pearson系数0.48),总体偏倚0.075 mm。
核心结论
- OCT是基底细胞癌体内诊断的可行工具。
- 频域OCT和高清OCT在诊断准确性和形态学特征识别上优于时域OCT,但在肿瘤深度评估上并不优于时域OCT。
研究设计与样本
- 定量综述,从已发表研究中提取肿瘤级原始数据,纳入31项研究共901个基底细胞癌。
- 纳入时域OCT、频域OCT和高清OCT系统诊断基底细胞癌的研究。
- 采用纽卡斯尔-渥太华量表和Cochrane偏倚风险工具进行质量评估。
主要发现
- OCT诊断基底细胞癌的总体灵敏度89.3%、特异度60.3%。
- 频域OCT的灵敏度93.7%、特异度61.4%,为各系统最高。
- 最常见形态学特征为小叶型(80.2%,315/393)和高反射瘤周间质(51.7%,203/393)。
- OCT与组织病理肿瘤深度分级的一致性为中等(Pearson系数0.48),在肿瘤<1 mm及四肢肿瘤中一致性最高。
- 总体偏倚0.075 mm,一致性范围-0.88至1.03 mm。
关键数值与推荐
- 诊断准确性以灵敏度和特异度评估,总体分别为89.3%和60.3%。
- 频域OCT灵敏度93.7%、特异度61.4%;高清OCT和频域OCT在识别形态学特征上优于时域OCT,但在肿瘤深度评估上不优于时域OCT。
- 肿瘤深度一致性以Pearson系数0.48评估,总体偏倚0.075 mm,一致性范围-0.88至1.03 mm。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Optical coherence tomography (OCT) is a noninvasive near-infrared light imaging technology that can be utilized to diagnose basal cell carcinomas (BCCs) based on specific morphological features. OBJECTIVES: To conduct a quantitative review using tumour-level data from published studies to assess: (i) the in vivo diagnostic accuracy of different OCT systems; (ii) correlation between OCT features and histopathological diagnosis; and (iii) factors that impact the accuracy of tumour depth estimation. METHODS: Primary tumour-level data were extracted from published studies on the use of time-domain (TD-OCT), frequency-domain (FD-OCT) and high-definition (HD-OCT) systems for diagnosis of BCCs. Quality assessment was performed using the Newcastle-Ottawa Scale and the Cochrane Risk of Bias Tool. Sensitivity and specificity for diagnosis of BCC, prevalence of morphological features and correlation of tumour depth between OCT and histopathology were analysed. RESULTS: In total, 901 BCCs from 31 studies were included. The sensitivity and specificity were 89·3% and 60·3% overall, and were highest for FD-OCT (93·7% and 61·4%, respectively). The most prevalent morphological features were lobular pattern (80·2%, 315 of 393 tumours) and hyper-reflective peritumoral stroma (51·7%, 203 of 393). Concordance between OCT and histopathological tumour depth categories was moderate (Pearson coefficient 0·48); it was highest for tumours < 1 mm and those on the extremities. The overall bias was 0·075 mm with an agreement range from -0·88 to 1·03 mm. HD-OCT and FD-OCT were superior to TD-OCT at identifying morphological features, but not at tumour depth estimation. CONCLUSIONS: OCT is a viable tool for in vivo diagnosis of BCCs. FD-OCT and HD-OCT outperformed TD-OCT in diagnostic accuracy and detection of morphological features, but not tumour depth estimation.
引用
- Reddy N, Nguyen BT. The utility of optical coherence tomography for diagnosis of basal cell carcinoma: a quantitative review. Br J Dermatol. 2018. PMID: 30216419. doi:10.1111/bjd.17201
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。