PubMed 文献 · Br J Dermatol · 2018-06-07

这项前瞻性盲法多中心研究纳入369例患者共476处色素性皮肤病变,在切除前进行皮肤镜和皮肤荧光镜检查。组织病理学证实101处(21.2%)为黑色素瘤,皮肤荧光镜灵敏度为89.1%(101处黑色素瘤中检出90处),特异度44.8%,阳性预测值30.3%,阴性预测值93.9%,未发生不良事件。

要点

  • 皮肤荧光镜检出黑色素瘤的灵敏度为89.1%,特异度为44.8%。
  • 阳性预测值30.3%,阴性预测值93.9%,未发生不良事件。
  • 缺乏足够黑色素荧光的无色素性或消退性病变是局限所在。

核心结论

  • 皮肤荧光镜是一种安全且准确的诊断方法,可辅助医生诊断皮肤黑色素瘤。
  • 对于缺乏足够黑色素荧光的无色素性或消退性病变,其应用存在局限。

研究设计与样本

  • 这是一项前瞻性、盲法、多中心临床研究,纳入369例患者共476处色素性皮肤病变。
  • 所有纳入病变在切除前行皮肤镜和体内皮肤荧光镜检查,随后切除行组织病理学检查。

主要发现

  • 476处病变中101处(21.2%)经组织病理学证实为黑色素瘤。
  • 皮肤荧光镜的灵敏度为89.1%(101处黑色素瘤中检出90处),特异度为44.8%。
  • 阳性预测值为30.3%,阴性预测值为93.9%。
  • 未发生不良事件。

局限性

  • 对于缺乏足够黑色素荧光的无色素性或消退性病变,皮肤荧光镜的应用存在局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Early detection is a key factor in improving survival from melanoma. Today, the clinical diagnosis of cutaneous melanoma is based mostly on visual inspection and dermoscopy. Preclinical studies in freshly excised or paraffin-embedded tissue have shown that the melanin fluorescence spectra after stepwise two-photon excitation, a process termed dermatofluoroscopy, differ between cutaneous melanoma and melanocytic naevi. However, confirmation from a larger prospective clinical study is lacking. OBJECTIVES: The primary end point of this study was to determine the diagnostic accuracy of dermatofluoroscopy in melanoma detection. Secondary end points included the collection of data for improving the computer algorithm that classifies skin lesions based on melanin fluorescence and the assessment of safety aspects. METHODS: This was a prospective, blinded, multicentre clinical study in patients with pigmented skin lesions (PSLs) indicated for excision either to rule out or to confirm cutaneous melanoma. All included lesions underwent dermoscopy and dermatofluoroscopy in vivo before lesions were excised and subjected to histopathological examination. RESULTS: In total, 369 patients and 476 PSLs were included in the final analysis. In 101 of 476 lesions (21·2%) histopathology revealed melanoma. The observed sensitivity of dermatofluoroscopy was 89·1% (90 of 101 melanomas identified), with an observed specificity of 44·8%. The positive and negative predictive values were 30·3% and 93·9%, respectively. No adverse events occurred. CONCLUSIONS: Dermatofluoroscopy is a safe and accurate diagnostic method to aid physicians in diagnosing cutaneous melanoma. Limitations arise from largely amelanotic or regressing lesions lacking sufficient melanin fluorescence.

来源:Br J Dermatol,查看原文。版权归原作者所有。

引用

  1. Forschner A, Keim U, Hofmann M, et al. Diagnostic accuracy of dermatofluoroscopy in cutaneous melanoma detection: results of a prospective multicentre clinical study in 476 pigmented lesions. Br J Dermatol. 2018. PMID: 29569229. doi:10.1111/bjd.16565

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。