热成像测量的皮肤表面温度有助于蜂窝织炎诊断
本研究纳入急诊疑似蜂窝织炎成人患者,随机分为皮肤科会诊组(n=40)和标准治疗组(n=32),用热成像测量患处与无患处皮肤温度。皮肤科会诊组中假性蜂窝织炎占28%。蜂窝织炎患者患处平均最高温度34.1°C,较对应无患处高3.7°C(95%CI 2.7-4.8°C,P<0.00001);假性蜂窝织炎患者患处平均最高温度31.5°C,较无患处高0.2°C(95%CI -1.1至1.5°C,P=0.44)。温差≥0.47°C诊断蜂窝织炎的敏感性96.6%、特异性45.5%、阳性预测值82.4%、阴性预测值83.3%,验证队列中准确率87.5%。
要点
- 蜂窝织炎患处与无患处温差平均3.7°C,假性蜂窝织炎仅0.2°C。
- 温差≥0.47°C诊断蜂窝织炎敏感性96.6%、特异性45.5%。
- 该模型验证队列中蜂窝织炎诊断准确率87.5%。
核心结论
- 热成像测量的患处与无患处皮肤温差有助于区分蜂窝织炎与假性蜂窝织炎。
研究设计与样本
- 前瞻性随机对照研究,纳入急诊疑似蜂窝织炎成人患者,皮肤科会诊组40例,标准治疗组32例,热成像分析建立预测模型并在另一队列验证。
主要发现
- 皮肤科会诊组中假性蜂窝织炎占28%。
- 蜂窝织炎患者患处平均最高温度34.1°C,较无患处高3.7°C(95%CI 2.7-4.8°C,P<0.00001)。
- 假性蜂窝织炎患者患处平均最高温度31.5°C,较无患处高0.2°C(95%CI -1.1至1.5°C,P=0.44)。
- 蜂窝织炎患者温差大于假性蜂窝织炎患者(3.7 vs. 0.2°C,P=0.002)。
关键数值与推荐
- 温差≥0.47°C诊断蜂窝织炎的敏感性96.6%、特异性45.5%、阳性预测值82.4%、阴性预测值83.3%。
- 验证队列中该模型正确诊断100%的蜂窝织炎患者和50%的假性蜂窝织炎患者。
- 温差≥0.47°C诊断蜂窝织炎的准确率为87.5%。
临床怎么用
- 热成像温差可作为辅助手段,帮助急诊区分蜂窝织炎与假性蜂窝织炎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Warmth is a characteristic but nondiagnostic feature of cellulitis. We assessed the diagnostic utility of skin surface temperature in differentiating cellulitis from pseudocellulitis. Adult patients presenting to the emergency department of a large urban hospital with presumed cellulitis were enrolled. Patients were randomized to dermatology consultation (n = 40) versus standard of care (n = 32). Thermal images of affected and unaffected skin were obtained for each patient. Analysis was performed on dermatology consultation patients to establish a predictive model for cellulitis, which was then validated in the other cohort. Of those evaluated by dermatology consultation, pseudocellulitis was diagnosed in 28%. Cellulitis patients had an average maximum affected skin temperature of 34.1°C, which was 3.7°C warmer than the corresponding unaffected area (95% confidence interval = 2.7-4.8°C, P < 0.00001). Pseudocellulitis patients had an average maximum affected temperature of 31.5°C, which was 0.2°C warmer than the corresponding unaffected area (95% confidence interval = -1.1 to 1.5°C, P = 0.44). Temperature differences between sites were greater in cellulitis patients than in pseudocellulitis patients (3.7 vs. 0.2°C, P = 0.002). A logistic regression model showed that a temperature difference of 0.47°C or greater conferred a 96.6% sensitivity, 45.5% specificity, 82.4% positive predictive value, and 83.3% negative predictive value for cellulitis diagnosis. When validated in the other cohort, this model gave the correct diagnosis for 100% of patients with cellulitis and 50% of those with pseudocellulitis. A difference threshold of 0.47°C or greater between affected and unaffected skin showed an 87.5% accuracy in cellulitis diagnosis.
引用
- Ko LN, Raff AB, Garza-Mayers AC, et al. Skin Surface Temperatures Measured by Thermal Imaging Aid in the Diagnosis of Cellulitis. J Invest Dermatol. 2017. PMID: 28951240. doi:10.1016/j.jid.2017.09.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。