标准化UV图像半自动分析客观评估白癜风靶皮损面积
本研究基于一项前瞻性双盲随机安慰剂对照试验,纳入20例稳定期白癜风患者,采用标准化UV反射图像半自动分析系统测量Target-VASI,并与描图纸法和临床医生评估比较。结果显示UV图像Target-VASI与描图纸法(r=0.81)及临床医生评估(r=0.89)均呈强相关,一致性良好,重复性中等至良好,提示该图像系统可作为传统方法的高效替代。
要点
- UV图像半自动分析测量Target-VASI与描图纸法及临床医生评估均呈强相关。
- UV图像Target-VASI与两种传统方法的一致性良好,重复性中等至良好。
- 该系统或可用于临床研究或常规实践,作为传统方法的高效替代。
核心结论
- 基于标准化UV反射图像半自动分析的Target-VASI测量性能可靠,可能作为传统方法的高效替代用于研究或常规临床实践。
研究设计与样本
- 验证性研究,嵌套于2023年9月至2024年2月在一家三级医疗中心开展的前瞻性双盲随机安慰剂对照临床试验。
- 纳入20例成人稳定期白癜风患者,每例有一对表面积2 cm²至20 cm²的靶皮损,1例失访,最终19例纳入分析。
- 在治疗前和治疗后12周,分别用UV图像系统、描图纸轮廓法和有经验临床医生评估三种方法测量Target-VASI。
主要发现
- UV图像Target-VASI与描图纸Target-VASI强相关(r=0.81 [95% CI, 0.71-0.89];P < .001)。
- UV图像Target-VASI与临床医生Target-VASI强相关(r=0.89 [95% CI, 0.83-0.93];P < .001)。
- 与描图纸法和临床医生评估的平均(SD)偏倚分别为0.81(0.99)和0.52(0.76),一致性良好。
- 组内相关系数为0.79(95% CI, 0.60-0.88),提示重复性中等至良好。
- 虽存在皮损区域不匹配和色素过度分割等错误,但因对脱色区域的精确检测,整体准确度基本维持。
临床怎么用
- 在临床研究或常规实践中,可考虑采用标准化UV图像半自动分析系统测量Target-VASI,以提高评估效率并减少评估者间变异。
局限性
- 研究样本量较小,最终仅19例纳入分析。
- 存在皮损区域不匹配和色素过度分割等图像分析错误。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: The Target Vitiligo Area Scoring Index (Target-VASI) is the primary tool for evaluating localized vitiligo lesions; however, its uncalibrated estimation in clinical practice is limited by intrarater and interrater variability. While objective methods using tracing papers or imaging systems are available, these approaches are often tedious and rely on images that are not well contrasted. OBJECTIVE: To assess the reliability and the performance of a semiautomatic analysis of the lesions performed on standardized UV reflectance pictures. DESIGN, SETTING, AND PARTICIPANTS: This validation study was part of a prospective, double-blind, randomized, placebo-controlled clinical trial conducted between September 2023 and February 2024 at a tertiary care center to evaluate a grafting-based therapy in difficult-to-treat vitiligo lesions. Participants included adult patients with a pair of stable vitiligo target lesions with surface areas between 2 cm2 and 20 cm2. Target-VASI was measured prior to treatment and 12 weeks after treatment by using 3 methods: the image-based system (UV image Target-VASI), tracing paper outlines (tracing paper Target-VASI), and assessments by an experienced clinician (clinician Target-VASI). The image-based system involved semiautomatic analysis of standardized UV reflectance images. MAIN OUTCOMES AND MEASURES: The Target-VASI estimation methods were compared for correlation, agreement, and repeatability, with relationships scored as weak, moderate, good/strong, and very good/very strong based on results. RESULTS: A total of 20 adult patients with a pair of stable vitiligo target lesions of surface area between 2 cm2 and 20 cm2 were enrolled. One was lost to follow-up, resulting in 19 evaluable participants included for the analysis. The mean (SD) age was 51.7 (10.7) years, and 12 (63.8%) were female. The mean (SD) vitiligo duration was 21.2 (14.4) years. A total of 61 tracing paper Target-VASIs and 76 UV image and clinician Target-VASIs were available for analysis. UV image Target-VASIs demonstrated strong correlations with tracing paper (r = 0.81 [95% CI, 0.71-0.89]; P < .001) and clinician (r = 0.89 [95% CI, 0.83-0.93]; P < .001) Target-VASIs. The agreement was also good, with mean (SD) biases of 0.81 (0.99) and 0.52 (0.76) for tracing paper and clinician Target-VASIs, respectively. Additionally, an intraclass correlation coefficient of 0.79 (95% CI, 0.60-0.88) indicated moderate to good reproducibility of Target-VASI measurements. Although errors, such as nonmatching lesion regions and oversegmented pigmentation, were identified, the overall UV image Target-VASI accuracy was largely maintained due to the precise detection of depigmented areas. CONCLUSIONS AND RELEVANCE: In this investigation, the image-based system demonstrated reliable performance, suggesting its possible use in studies or routine clinical practice as a more efficient alternative to conventional approaches.
引用
- Jabour C, Bletterer A, Passeron T, et al. Objective Assessment of Target Vitiligo Areas by Semiautomatic Analysis of Standardized UV Images. JAMA Dermatol. 2025. PMID: 40960816. doi:10.1001/jamadermatol.2025.2740
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。