文献速递皮肤肿瘤

皮肤镜与反射共聚焦显微镜诊断基底细胞癌的前瞻性多中心研究

Dermatoscopy and reflectance confocal microscopy for basal cell carcinoma diagnosis and diagnosis prediction score: A prospective and multicenter study on 1005 lesions.
PubMed 文献 · J Am Acad Dermatol · 2024-01-30

这项在意大利3个中心开展的前瞻性研究纳入1005个临床疑似基底细胞癌的病灶,比较单用皮肤镜与联合手持反射共聚焦显微镜(RCM)的诊断准确性。联合RCM的敏感度97.8%、特异度86.8%,均高于单用皮肤镜的93.2%和51.7%,假阴性极少。

要点

  • 联合手持RCM可提高基底细胞癌诊断敏感度和特异度。
  • 单用皮肤镜特异度仅51.7%,联合RCM升至86.8%。
  • 联合RCM假阴性病灶极少,适合临床疑似病例的辅助评估。

核心结论

  • 对临床疑似基底细胞癌的病灶,联合手持RCM评估可获得更高的诊断准确性且假阴性极少。

研究设计与样本

  • 前瞻性多中心研究,在意大利3个皮肤癌参考中心连续纳入临床-皮肤镜疑似基底细胞癌的病灶(ClinicalTrials.gov: NCT04789421)。
  • 共纳入1005个病灶,其中474个经组织病理学确诊,531个经临床-皮肤镜-RCM相关性诊断并以2年随访确认;最终740个确诊为基底细胞癌。

主要发现

  • 单用皮肤镜的敏感度为93.2%(95% CI, 91.2-94.9),特异度为51.7%(95% CI, 45.5-57.9)。
  • 单用皮肤镜的阳性预测值为84.4(95% CI, 81.7-86.8),阴性预测值为73.3(95% CI, 66.3-79.5)。
  • 联合RCM的敏感度为97.8%(95% CI, 96.5-98.8),特异度为86.8%(95% CI, 82.1-90.6)。
  • 联合RCM的阳性预测值为95.4(95% CI, 93.6-96.8),阴性预测值为93.5(95% CI, 89.7-96.2)。

临床怎么用

  • 对临床-皮肤镜疑似基底细胞癌的病灶,可加用手持RCM评估以提高诊断准确性并减少假阴性。

局限性

  • 研究仅在单一国家开展。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Basal cell carcinoma (BCC) is usually diagnosed by clinical and dermatoscopy examination, but diagnostic accuracy may be suboptimal. Reflectance confocal microscopy (RCM) imaging increases skin cancer diagnostic accuracy. OBJECTIVE: To evaluate additional benefit in diagnostic accuracy of handheld RCM in a prospective controlled clinical setting. METHODS: A prospective, multicenter study in 3 skin cancer reference centers in Italy enrolling consecutive lesions with clinical-dermatoscopic suspicion of BCC (ClinicalTrials.gov: NCT04789421). RESULTS: A total of 1005 lesions were included, of which 474 histopathologically confirmed versus 531 diagnosed by clinical-dermatoscopic-RCM correlation, confirmed with 2 years of follow-up. Specifically, 740 were confirmed BCCs. Sensitivity and specificity for dermatoscopy alone was 93.2% (95% CI, 91.2-94.9) and 51.7% (95% CI, 45.5-57.9); positive predictive value was 84.4 (95% CI, 81.7-86.8) and negative predictive value 73.3 (95% CI, 66.3-79.5). Adjunctive RCM reported higher rates: 97.8 (95% CI, 96.5-98.8) sensitivity and 86.8 (95% CI, 82.1-90.6) specificity, with positive predictive value of 95.4 (95% CI, 93.6-96.8) and negative predictive value 93.5 (95% CI, 89.7-96.2). LIMITATIONS: Study conducted in a single country. CONCLUSIONS: Adjunctive handheld RCM assessment of lesions clinically suspicious for BCC permits higher diagnostic accuracy with minimal false negative lesions.

来源:J Am Acad Dermatol,查看原文。版权归原作者所有。

引用

  1. Longo C, Guida S, Mirra M, et al. Dermatoscopy and reflectance confocal microscopy for basal cell carcinoma diagnosis and diagnosis prediction score: A prospective and multicenter study on 1005 lesions. J Am Acad Dermatol. 2024. PMID: 38296197. doi:10.1016/j.jaad.2024.01.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。