反射式共聚焦显微镜辅助鉴别面外恶性雀斑样痣:回顾性多中心病例对照研究
本研究纳入48例组织学确诊的面外恶性雀斑样痣(EF-LM)薄黑素瘤与45例对照病变(日光性黑子、苔藓样角化病、脂溢性角化病、黑素细胞痣),回顾性分析临床、皮肤镜与反射式共聚焦显微镜(RCM)特征。EF-LM更常见雀斑样色素模式、角化线与锯齿状结构;RCM鉴别诊断敏感度90%、特异度97%。
要点
- EF-LM皮肤镜常见雀斑样色素模式、角化线与锯齿状结构,缺乏经典浅表扩散型黑素瘤特征。
- RCM下EF-LM更常见Paget样播散、表皮内圆细胞与树突细胞、真皮表皮交界处异型细胞与树突细胞、网格模式及弹性纤维增生。
- RCM用于鉴别EF-LM与模拟病变的敏感度90%、特异度97%。
核心结论
- 面外恶性雀斑样痣不具有浅表扩散型黑素瘤的经典皮肤镜特征,最常见皮肤镜标准为角化线和无雀斑样边界的雀斑样色素模式。
- RCM可作为评估皮肤镜下可疑病变的有价值成像工具,突出提示黑素瘤的细胞异型性。
研究设计与样本
- 回顾性多中心病例对照研究,从数据库中选取48例光损伤皮肤上具有EF-LM组织学特征的薄黑素瘤病例,及45例可作鉴别诊断的对照病变(日光性黑子、苔藓样角化病、脂溢性角化病、黑素细胞痣)。
主要发现
- EF-LM较对照更常见雀斑样色素模式、角化线和锯齿状结构。
- RCM下EF-LM较对照更常见Paget样播散、表皮内圆细胞、表皮内树突细胞、真皮表皮交界处异型细胞、交界处树突细胞、网格模式和弹性纤维增生。
- RCM鉴别诊断EF-LM的敏感度为90%,特异度为97%。
关键数值与推荐
- RCM鉴别EF-LM的敏感度90%、特异度97%。
临床怎么用
- 对皮肤镜下可疑病变,RCM可突出显示提示黑素瘤的细胞异型性,作为评估工具。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Extra facial lentigo maligna (EF-LM) arises outside the head and neck area. EF-LM presents the classic histological features of lentigo maligna. The dermoscopic aspects of EF-LM have been poorly studied. OBJECTIVE: The primary aims of our study were to analyse and describe the clinical, dermoscopic and confocal microscopy features of a series of histologically confirmed EF-LM. METHOD: We conducted a retrospective and multicentric study. From our database, we selected 48 cases of thin melanomas on photodamaged skin with histological features of EF-LM of which clinical, dermoscopic and confocal microscopy images were available, and a control group of 45 lesions, that can be subjected to differential diagnosis such as solar lentigo, lichenoid keratosis, seborrheic keratosis and melanocytic nevi, of which dermoscopic and confocal microscope images were available. RESULTS: Extra facial lentigo maligna had a higher prevalence of lentigo-like pigment patterns, angulated lines and zigzag structures. At confocal microscopy, LM-EF cases showed a higher prevalence of pagetoid spreading, round cells, dendritic cells in the epidermis, atypical cells at the dermo-epidermal junction, dendritic cells at the junction, meshwork pattern and elastosis. Our study shows that reflectance confocal microscopy (RCM) has a sensitivity of 90% and a specificity of 97% for the differential diagnosis of this type of melanoma. CONCLUSIONS: Extra facial lentigo maligna does not have the classic dermoscopic features of superficial spreading melanoma, the most observed dermoscopic criteria are angulated lines and lentigo-like pigment patterns without lentigo-like border. RCM can be a valuable imaging tool for the evaluation of all those suspicion skin lesions at dermoscopy highlighting cellular atypia suggestive for melanoma.
引用
- Licata G, Brancaccio G, Ronchi A, et al. Is reflectance confocal microscopy useful in the differential diagnosis of extra facial lentigo maligna? A retrospective multicentric case-control study. J Eur Acad Dermatol Venereol. 2023. PMID: 37478292. doi:10.1111/jdv.19379
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。