研究设计与样本
- 研究纳入14例钴接触过敏者,采用斑贴试验暴露于CoNPs、CoCl2、含钴硬金属盘(阳性对照)和空试验腔(阴性对照)。
- 第2、4、7天由皮肤科医生临床评估过敏反应;第2天移除斑贴试验腔并收集残留测试物和皮肤擦拭样本行电感耦合等离子体质谱(ICP-MS)分析。
- 第4天取斑贴试验反应处皮肤活检,行定量实时聚合酶链反应分析、组织病理学和ICP-MS分析钴的皮肤渗透。
主要发现
- 斑贴试验中CoNPs在钴致敏个体中引发过敏反应。
- 所有时间点临床评估显示,CoNPs阳性斑贴试验反应频率显著低于CoCl2或阳性对照。
- CoNPs引发的免疫反应与CoCl2相当。
- 斑贴试验滤器和皮肤上钴残留的化学分析显示,CoNPs的剂量低于CoCl2。
局限性
- 需进一步研究以明确CoNPs对人类健康的潜在危害。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cobalt (Co) causes allergic contact dermatitis (ACD) and the emerging use of Co nanoparticles (CoNPs) warrants gaining further insight into its potential to elicit ACD in sensitized individuals. OBJECTIVES: The aims of the study were to clarify to what extent CoNPs may elicit ACD responses in participants with Co contact allergy, and to evaluate whether the nanoparticles cause a distinct immune response compared with cobalt chloride (CoCl2) in the skin reactions. METHODS: Fourteen individuals with Co contact allergy were exposed to CoNPs, CoCl2, a Co-containing hard-metal disc (positive control), and an empty test chamber (negative control) by patch testing. Allergic responses were evaluated clinically by a dermatologist at Days 2, 4 and 7. At Day 2, patch-test chambers were removed, and remaining test-substance and skin-wipe samples were collected for inductive-coupled plasma mass spectrometry (ICP-MS) analysis. Additionally, skin biopsies were taken from patch-test reactions at Day 4 for quantitative real-time polymerase chain reaction analysis, histopathology and ICP-MS analysis of Co skin penetration. RESULTS: Patch testing with CoNPs elicited allergic reactions in Co-sensitized individuals. At all timepoints, clinical assessment revealed significantly lower frequencies of positive patch-test reactions to CoNPs compared with CoCl2 or to the positive control. CoNPs elicited comparable immune responses to CoCl2. Chemical analysis of Co residues in patch-test filters, and on skin, shows lower doses for CoNPs compared with CoCl2. CONCLUSIONS: CoNPs potently elicit immune responses in Co-sensitized individuals. Even though patch testing with CoNPs resulted in a lower skin dose than CoCl2, identical immunological profiles were present. Further research is needed to identify the potential harm of CoNPs to human health.
引用
- Midander K, Werner P, Isaksson M, et al. Cobalt nanoparticles cause allergic contact dermatitis in humans. Br J Dermatol. 2023. PMID: 36637098. doi:10.1093/bjd/ljac043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。