文献速递牙周病口腔修复与种植

口内超声评估中颊侧探诊深度的概念验证临床一致性研究

Intraoral Ultrasonography for Mid‐Buccal Probing Depth Assessment: A Proof‐of‐Concept Clinical Agreement Study
RSS 订阅 · Journal of Clinical Periodontology · 2026-10-16

本研究在69名参与者963个中颊侧位点比较超声测量龈沟深度与临床探诊深度的一致性。结果显示两者ICC为0.942,平均差异仅+0.023 mm,提示口内超声可作为传统探诊的非侵入性辅助手段。

要点

  • 口内超声与临床探诊深度在中颊侧位点一致性高(ICC=0.942)。
  • 85.0%位点差异≤0.50 mm,96.7%位点差异≤1.00 mm。
  • 磨牙位点误差最大(MAE=0.38 mm)且略低估探诊深度。

核心结论

  • 口内超声与临床探诊深度在标准化中颊侧位点高度一致,可作为非侵入性辅助检查。

研究设计与样本

  • 概念验证临床一致性研究,纳入69名参与者共963个中颊侧位点(767前牙、127前磨牙、69第一磨牙)。
  • 使用18 MHz超声探头与UNC-15探针测量,由两名经培训检查者评估可靠性。

主要发现

  • 超声测量可靠性高(ICC>0.90)。
  • uGSD与临床PD的ICC=0.942(95% CI: 0.935–0.949),平均差异+0.023 mm,MAE=0.29±0.32 mm。
  • 亚组ICC范围为0.786至0.952;85.0%位点差异≤0.50 mm,96.7%位点差异≤1.00 mm。
  • 磨牙位点MAE最高(0.38 mm)且轻微低估(−0.123 mm)。

关键数值与推荐

  • 一致性评价采用ICC、Bland–Altman分析和MAE,并用广义估计方程和聚类ICC处理患者内聚类。
  • 亚组包括PD分层、出血、牙类型、牙石、修复体(冠/正畸附件)和吸烟。

临床怎么用

  • 口内超声可作为传统探诊的非侵入性辅助手段用于中颊侧位点评估。
  • 磨牙位点需注意轻微低估和较高误差。

局限性

  • 需更广泛研究覆盖复杂位点和不同检查者经验水平。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT Aim To evaluate the agreement between ultrasound-derived gingival sulcus depth (uGSD) and clinical probing depth (PD) at standardised mid-buccal sites as a proof-of-concept study. Materials and Methods Mid-buccal measurements were obtained from 963 sites in 69 participants (767 anterior, 127 premolars, 69 first molars) using an 18-MHz ultrasound transducer and a UNC-15 probe. uGSD was measured on B-mode images; reliability was assessed by two trained examiners. Agreement was evaluated using intra-class correlation coefficient (ICC), Bland–Altman analysis and mean absolute error (MAE). Generalised estimating equations and clustered ICCs accounted for within-patient clustering. Subgroups included PD strata, bleeding, tooth type, calculus, restorations (prosthetic crowns/orthodontic attachments) and smoking. Results Ultrasound measurements showed high reliability (ICCs > 0.90). Agreement between uGSD and clinical PD was strong (ICC = 0.942; 95% CI: 0.935–0.949), with negligible mean difference (+0.023 mm) and low MAE (0.29 ± 0.32 mm). Subgroup ICCs ranged from 0.786 to 0.952; 85.0% of sites differed by ≤ 0.50 mm and 96.7% by ≤ 1.00 mm. Molar sites showed the highest MAE (0.38 mm) and slight underestimation (−0.123 mm). Conclusion Intraoral ultrasonography showed high agreement with clinical PD at standardised mid-buccal sites in anterior teeth, premolars and first molars. It may serve as a non-invasive adjunct to conventional probing; however, broader studies are needed across complex sites and examiner experience levels.

来源:Journal of Clinical Periodontology,查看原文。版权归原作者所有。

引用

  1. Journal of Clinical Periodontology:Intraoral Ultrasonography for Mid‐Buccal Probing Depth Assessment: A Proof‐of‐Concept Clinical Agreement Study

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。