文献速递牙周病口腔修复与种植

种植体颈部机加工与激光微织构表面对牙周及种植周组织愈合的影响

Sulcus fluid volume, IL-6, and Il-1b concentrations in periodontal and peri-implant tissues comparing machined and laser-microtextured collar/abutment surfaces during 12 weeks of healing: A split-mouth RCT.
PubMed 文献 · Clin Oral Implants Res · 2021-10-16

结果显示MS位点探诊深度与出血指数均值显著高于LMS位点;术后1–4周两组种植周组织与手术牙周组织均呈较高炎症状态,至12周仅MS位点仍维持较高炎症状态,LMS位点则与牙周组织相近。

要点

  • MS位点探诊深度与出血指数均值显著高于LMS位点(p<0.05)。
  • 术后1–4周MS与LMS种植周组织及手术牙周组织龈沟液量变化无显著差异。
  • 6–12周LMS位点龈沟液量及IL-6、IL-1β浓度与手术牙周组织无显著差异,MS位点显著更高。

核心结论

  • 与手术及非手术牙周组织相比,MS与LMS种植位点在术后早期(1–4周)均呈较高促炎状态。
  • 至12周,仅MS种植位点维持较高促炎状态,LMS位点则与手术及非手术牙周组织相近。

研究设计与样本

  • 每位患者一枚种植体采用MS颈圈及MS即刻愈合基台,另一枚采用LMS颈圈及LMS即刻愈合基台。
  • 比较手术牙周组织(T+)与非手术牙周组织(T-)及MS、LMS种植位点的软组织愈合。
  • 于基线及1、2、3、4、6、8、12周评估临床与生化指标。

主要发现

  • MS位点探诊深度与出血指数均值显著高于LMS位点(p<0.05)。
  • 早期愈合阶段(1–4周),MS与LMS种植周组织及T(+)牙周组织龈沟液量变化无统计学显著差异(p>0.05)。
  • 6–12周,LMS位点龈沟液量及IL-6、IL-1β浓度与T(+)无统计学显著差异(p>0.05)。
  • 6–12周,MS位点上述指标均值显著高于T(+)(p<0.05)。

关键数值与推荐

  • PD与BoP均值:MS位点显著高于LMS位点(p<0.05)。
  • 1–4周龈沟液量变化:MS、LMS与T(+)间无显著差异(p>0.05)。
  • 6–12周龈沟液量及IL-6、IL-1β浓度:LMS与T(+)无显著差异(p>0.05),MS显著高于T(+)(p<0.05)。

临床怎么用

  • 提示激光微织构颈圈与基台表面在12周愈合期内可能更有利于种植周软组织炎症消退。
  • 临床评估种植周软组织愈合时可结合探诊深度、出血指数及龈沟液炎症因子动态观察。
  • 机加工表面种植位点在术后早期至12周需关注其较高促炎状态。

局限性

  • 样本为非吸烟患者,结果外推至吸烟人群需谨慎。
  • 随访仅至12周,缺乏长期骨整合与软组织稳定性数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare gingival tissue healing at surgically manipulated periodontal sites and at sites receiving implants and healing abutments with machined (MS) vs laser-microtextured (LMS) surface placed with one-stage protocol. MATERIAL AND METHODS: Twenty-four non-smoking patients each received two implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one implant with a MS collar and one immediate healing abutment with a MS, and one implant with a LMS collar and one immediate healing abutment with a LMS were used. Soft tissues healing at surgically manipulated periodontal tissues (T+) and at non-surgically manipulated periodontal tissues (T-) at MS implant sites and at LMS implant sites were compared by means of clinical and biochemical parameters at baseline and at 1-2-3-4-6-8 and 12 weeks. RESULTS: PD and BoP mean values were statistically higher in MS than LMS implant sites (p<0.05). During early healing phase (1-4 weeks), MS and LMS peri-implant tissues and periodontal tissues at T(+) showed no statistically significant difference in crevicular fluid volume changes (p>0.05). Between 6 and 12 weeks, compared with T(+), no statistically significant difference in crevicular fluid volume and IL-6 and IL-1β concentrations was noted in LMS implant sites (p>0.05), while statistically significantly higher mean values were noted in MS implant sites (p<0.05). CONCLUSIONS: Compared with T(+) and T(-), both MS and LMS implant sites presented a higher pro-inflammatory state in the early phase after surgery (1-4 weeks). At 12 weeks, only MS implant sites kept a higher pro-inflammatory state, while at LMS implant sites, it becomes similar to T(+) and T(-).

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Guarnieri R, Miccoli G, Reda R, et al. Sulcus fluid volume, IL-6, and Il-1b concentrations in periodontal and peri-implant tissues comparing machined and laser-microtextured collar/abutment surfaces during 12 weeks of healing: A split-mouth RCT. Clin Oral Implants Res. 2021. PMID: 34624157. doi:10.1111/clr.13868

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。