文献速递口腔修复与种植

种植体水平连接用于螺丝固位固定局部义齿的3年随机临床试验

The use of implant-level connection in screw-retained fixed partial dentures: A 3-year randomised clinical trial.
PubMed 文献 · Clin Oral Implants Res · 2021-10-12

本随机对照试验比较内锥形连接种植体支持螺丝固位固定局部义齿时,基台水平(AL)与种植体水平(IL)连接3年后的边缘骨水平变化及临床参数。50例患者共119枚种植体随机分组,结果显示两组边缘骨水平变化无显著差异,软组织并发症的轻微差异可能无临床意义,IL连接可作为AL方案的有效替代。

要点

  • 内锥形连接种植体支持螺丝固位固定局部义齿时,IL与AL连接的3年边缘骨水平变化无显著差异。
  • 探诊出血在1至2年间两组差异显著(p=.025),但软组织并发症的轻微差异可能无临床意义。
  • IL连接被认为是内锥形连接种植体中AL方案的有效替代。

核心结论

  • 两组边缘骨水平变化相似,软组织并发症的轻微差异可能无临床意义,IL连接可作为ICC种植体中AL方案的有效替代。

研究设计与样本

  • 随机对照试验,50例患者共119枚种植体随机分配至AL组或IL组,术后1、2、3年进行影像学和临床检查,采用线性混合模型评估组间差异。

主要发现

  • 边缘骨水平变化在各时间点组间均无显著差异:1年时AL为0.12±0.31 mm、IL为0.23±0.26 mm;2年时AL为0.15±0.34 mm、IL为0.17±0.22 mm;3年时AL为0.18±0.39 mm、IL为0.15±0.21 mm。
  • 探诊出血1年时AL为43.44±39.24%、IL为58.19±41.20%;2年时AL为35.78±39.22%、IL为50.43±41.49%;3年时AL为51.27±44.63%、IL为49.57±37.31%;1至2年间组间差异显著(p=.025)。
  • 探诊深度各时间点组间差异显著,而菌斑组间无显著差异。
  • 总体技术、生物学和修复并发症发生率分别为5.04%、3.36%和16.00%。

临床怎么用

  • 在内锥形连接种植体支持螺丝固位固定局部义齿时,种植体水平连接可作为基台水平连接的有效替代方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This randomised controlled trial compares the 3-year outcomes, that is, marginal bone-level (MBL) changes and clinical parameters, between an abutment-level (AL) and implant-level (IL) connection for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. MATERIAL AND METHODS: Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic and clinical examinations were performed after one, two, and 3 years. A linear mixed model was used to evaluate the differences between groups. RESULTS: The MBL change was not significantly different between the groups at any point. The MBL was 0.12 ± 0.31 mm (AL) and 0.23 ± 0.26 mm (IL) after 1 year; 0.15 ± 0.34 mm (AL) and 0.17 ± 0.22 mm (IL) after 2 years; 0.18 ± 0.39 mm (AL) and 0.15 ± 0.21 mm (IL) after 3 years. The bleeding on probing was 43.44 ± 39.24% (AL) and 58.19 ± 41.20% (IL) after 1 year; 35.78 ± 39.22% (AL) and 50.43 ± 41.49% (IL) after 2 years; 51.27 ± 44.63% (AL) and 49.57 ± 37.31% (IL) after 3 years and was significantly different (p = .025) between 1 and 2 years. The probing depth showed a significant difference at each time point while the plaque was not significant between the groups. The overall technical, biological and prosthetic complication rates were 5.04%, 3.36%, and 16.00%, respectively. CONCLUSIONS: The MBL change was similar in the groups. The slight differences in the soft tissue complications between the groups are likely not of clinical relevance. An IL connection is considered to be a valid alternative to an AL set-up in ICC implants.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Toia M, Stocchero M, Galli S, et al. The use of implant-level connection in screw-retained fixed partial dentures: A 3-year randomised clinical trial. Clin Oral Implants Res. 2021. PMID: 34617341. doi:10.1111/clr.13867

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。