文献速递牙体牙髓病

热处理镍钛器械对弯曲根管生物力学预备的影响:micro-CT 评价

Impact of several NiTi-thermally treated instrumentation systems on biomechanical preparation of curved root canals in extracted mandibular molars.
PubMed 文献 · Int Endod J · 2021-11-04

本研究用 micro-CT 评价 R-Motion、Reciproc Blue、HyFlex CM 和 XP-endo Shaper 预备离体下颌磨牙中度与重度弯曲根管的成形能力。结果显示 Reciproc Blue 与 XP-endo Shaper 在中三分之一横截面积和体积增加更大,Reciproc Blue 最小牙本质厚度更小;XP-endo Shaper 与 R-Motion 以较少牙本质去除获得类似成形效果。

要点

  • Reciproc Blue 与 XP-endo Shaper 在中三分之一横截面积增加显著大于 R-Motion 与 HyFlex CM。
  • Reciproc Blue 使用后危险区与安全区最小牙本质厚度显著更小。
  • XP-endo Shaper 与 R-Motion 以较少牙本质去除获得类似大锥度器械的成形能力。

核心结论

  • XP-endo Shaper 与 R-Motion 在离体下颌磨牙弯曲近中根管中,以较少危险区与安全区牙本质去除获得与更大锥度器械类似的成形能力。

研究设计与样本

  • 离体下颌磨牙弯曲近中根随机分为 4 组(n=10),以 micro-CT 评价成形能力。

主要发现

  • Reciproc Blue 与 XP-endo Shaper 仅在中三分之一横截面积平均增加显著大于 R-Motion 与 HyFlex CM(p < .05)。
  • Reciproc Blue 与 XP-endo Shaper 体积平均增加显著大于 R-Motion 与 HyFlex CM(p < .05)。
  • R-Motion 预备后 SMI 差值显著低于 Reciproc Blue、HyFlex CM 与 XP-endo Shaper(p < .05)。
  • Reciproc Blue 使用后在危险区与安全区观察到最小牙本质厚度(p < .05)。
  • R-Motion、Reciproc Blue 与 XP-endo Shaper 周长长度与宽度增加相似(p > .05),HyFlex CM 周长平均增加仅显著低于 XP-endo Shaper(p < .05)。

关键数值与推荐

  • 器械参数:R-Motion 30 号 0.04 锥度,Reciproc Blue 25 号 0.08 锥度,HyFlex CM 30 号 0.04 锥度,XP-endo Shaper 30 号 0.01 锥度。
  • 冲洗液为 10 ml 2.5% NaOCl。
  • 样本固定于浸没 37°C 水的容器中完成整个预备过程。
  • 统计分析采用方差分析与 Tukey 事后检验(α = 5%)。

临床怎么用

  • 在弯曲根管预备中可考虑 XP-endo Shaper 或 R-Motion 以保留更多牙本质。
  • 使用 Reciproc Blue 时需注意危险区与安全区牙本质厚度减小。

局限性

  • 研究为离体牙实验室台旁实验,结果需临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. de Carvalho KKT, Petean IBF, Silva-Sousa AC, et al. Impact of several NiTi-thermally treated instrumentation systems on biomechanical preparation of curved root canals in extracted mandibular molars. Int Endod J. 2021. PMID: 34687053. doi:10.1111/iej.13649

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。