文献速递牙体牙髓病

开髓洞型对往复器械预备下颌磨牙近中根管牙本质厚度的影响

Influence of access cavity preparation on the dentine thickness of mesial canals of mandibular molars prepared with reciprocating instruments.
PubMed 文献 · Int Endod J · 2021-10-21

本研究用微计算机断层扫描评估传统与保守开髓洞型对离体下颌磨牙近中根管冠三分之一剩余牙本质厚度的影响,使用往复器械预备。结果显示预备后牙本质厚度均减少,但两种开髓洞型间牙本质减少百分比无差异,根管远中面减少更显著。

要点

  • 传统与保守开髓洞型对近中根管冠部剩余牙本质厚度无显著影响。
  • 预备后根管远中面牙本质减少更明显,且易出现厚度小于0.5 mm区域。
  • 开髓洞型选择不影响远中面牙本质厚度小于0.5 mm的发生率。

核心结论

  • 传统或保守开髓洞型不影响经往复镍钛器械预备的下颌磨牙近中根管冠三分之一剩余牙本质厚度。

研究设计与样本

  • 使用Reciproc Blue R25和R40器械预备根管,预备前后扫描并配准,测量根分叉水平至根尖方向5 mm内每1 mm间隔的牙本质最小厚度。
  • 统计分析采用配对样本t检验、独立样本t检验和卡方检验,显著性水平5%。

主要发现

  • 两组所有水平预备后牙本质厚度均小于预备前(p < .05)。
  • 传统开髓组与保守开髓组牙本质减少百分比无差异(p > .05),但根远中面减少显著更大(p < .05)。
  • 预备后牙本质厚度小于0.5 mm主要见于根远中面(10%至15%),开髓类型对近中(X2 = 1.66; p = .2)或远中(X2 = 0.40; p = .5)方向的发生率无影响。
  • 传统开髓组预备后多数切片牙本质厚度大于1.0 mm(n = 124),保守开髓组多在0.5至1.0 mm(n = 136)。

临床怎么用

  • 在采用往复镍钛器械预备下颌磨牙近中根管时,传统与保守开髓洞型对冠部剩余牙本质厚度影响相似,可依据临床需要选择开髓方式。
  • 需注意根管远中面牙本质减少更明显,预备时应关注该区域以避免过度切削。

局限性

  • 研究为离体牙实验,结果可能不完全适用于临床活体情况。
  • 样本量较小(每组10颗),可能影响统计效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate the influence of traditional and conservative access cavity preparations on the remaining dentine thickness in the coronal third of mesial canals of extracted mandibular molars prepared with reciprocating instruments using micro-computed tomography as the analytical tool. METHODOLOGY: Seventy extracted mandibular molars were scanned at a pixel size of 19 μm. From this initial sample, 20 teeth were selected, pair-matched and distributed into two groups (n = 10) according to the access cavity preparation: traditional (TradAC) or conservative (ConsAC). The root canals were sequentially enlarged with Reciproc Blue R25 (size 25, 0.08v taper) and R40 (size 40, 0.06v taper) instruments. A new scan was performed and the postoperative stacks were coregistered with their respective preoperative datasets. A colour-coded cross sections of the roots were created and used to identify and measure the smallest dentine thickness related to both MB and ML canals at 1.0-mm intervals from the furcation level of up to 5 mm in the apical direction, in both mesial and distal aspects of the roots, before and after preparation. The statistical analyses were performed with paired-samples t-test, independent-samples Student T-test and Chi-Square test with a significance level of 5%. RESULTS: At all levels of both groups, dentine thickness before preparation was greater than after preparation (p < .05). No difference in the percentage of dentine reduction was observed between TradAC and ConsAC groups (p > .05), but a significantly greater reduction was observed to the distal aspect of the roots (p < .05). After root canal preparation, dentine thinner than 0.5 mm was observed mostly along the distal aspect of the root (10% to 15%) of the MB and ML canals, with no influence of the access cavity type on its incidence to either mesial (X2 = 1.66; p = .2) or distal (X2 = 0.40; p = .5) directions. In the TradAC group, dentine thickness in most slices was greater than 1.0 mm after preparation (n = 124) whilst, in the ConsAC, it ranged from 0.5 to 1.0 mm (n = 136). CONCLUSION: Traditional or conservative access cavity preparation in extracted mandibular molars did not influence the remaining dentine thickness in the coronal third of mesial canals enlarged with thermomechanically treated nickel-titanium reciprocating instruments.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Silva EJNL, Lima CO, Barbosa AFA, et al. Influence of access cavity preparation on the dentine thickness of mesial canals of mandibular molars prepared with reciprocating instruments. Int Endod J. 2021. PMID: 34601728. doi:10.1111/iej.13642

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。