文献速递口腔修复与种植口腔颌面外科

后牙单颗缺失静态计算机辅助种植手术不同手术导板设计的比较回顾性研究

A comparative retrospective study of different surgical guide designs for static computer-assisted implant surgery in posterior single edentulous sites.
PubMed 文献 · Clin Oral Implants Res · 2021-10-11

结果显示组间角度偏差无统计学差异,但无边界牙支持组与有边界牙支持组在基部和尖部三维偏移上存在显著差异,提示无边界位点增加软组织支持可能更有利。

要点

  • 后牙单颗缺失不同导板设计可能影响sCAIS精度。
  • 无边界位点增加后部附着软组织支持可能更有利。
  • 组间角度偏差无统计学显著差异。

核心结论

  • 后牙单颗缺失区不同手术导板设计似乎与sCAIS精度水平相关。
  • 在无边界位点,增加后部附着软组织支持更可取。

研究设计与样本

  • 所有患者使用相应手术导板行全引导种植手术,评估术前计划与术后种植体位置偏差。

主要发现

  • 角度偏差均值±标准差:Group 1为2.91±1.56°,Group 2为3.33±1.72°,Group 3为2.25±1.13°。
  • 基部三维偏移均值±标准差:Group 1为0.66±0.29 mm,Group 2为0.77±0.24 mm,Group 3为0.49±0.22 mm。
  • 尖部三维偏移均值±标准差:Group 1为0.84±0.45 mm,Group 2为1.07±0.38 mm,Group 3为0.75±0.25 mm。
  • 组间角度偏差无统计学显著差异。
  • Group 2与Group 3在基部三维偏移(p = .002)和尖部三维偏移(p = .010)上存在统计学显著差异。

临床怎么用

  • 后牙单颗缺失行sCAIS时,无边界位点可考虑增加后部附着软组织支持以提升精度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The aim of this retrospective clinical study was to compare the accuracy of static Computer-assisted implant surgery (sCAIS) in posterior single edentulous patients using different surgical guide designs. MATERIALS AND METHODS: Thirty-seven partially edentulous patients with a total of 54 implants were included in the study. Seventeen implants were included in Group 1-Unbounded Tooth-Mucosa Supported; 18 implants in Group 2-Unbounded Tooth Supported; and 19 implants in Group 3 (Control)-Bounded Tooth Supported. All partially edentulous patients were treated with fully guided implant surgery using the corresponding surgical guide. Discrepancies between the pre-planned and post-operative implant position were evaluated. RESULTS: The mean angular deviation ± standard deviation (SD) was 2.91 ± 1.56°, 3.33 ± 1.72° and 2.25 ± 1.13° for Groups 1, 2, and 3, respectively. The mean ± SD 3D offset at base was 0.66 ± 0.29 mm, 0.77 ± 0.24 mm, and 0.49 ± 0.22 mm; and 3D offset at tip was 0.84 ± 0.45 mm, 1.07 ± 0.38 mm, and 0.75 ± 0.25 mm for Groups 1, 2, and 3, respectively. No statistically significant differences between groups were found for angular deviation. There were statistically significant differences between Groups 2 and 3 for 3D offset at base (p = .002) and 3D offset at tip (p = .010). CONCLUSIONS: Different surgical guide designs for posterior single edentulous areas appear to be associated with the accuracy level of sCAIS. In unbounded sites, having additional posterior attached soft tissue support is preferable.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. De Souza AB, Kang M, Negreiros WM, et al. A comparative retrospective study of different surgical guide designs for static computer-assisted implant surgery in posterior single edentulous sites. Clin Oral Implants Res. 2021. PMID: 34587320. doi:10.1111/clr.13858

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。