三种根管锉系统在下颌磨牙椭圆形远中根管成形能力的micro-CT分析
该研究采用micro-CT比较WaveOne Gold、TRUShape和XP-endo Shaper在离体下颌磨牙椭圆形远中根管中的成形能力。结果显示XP-endo Shaper的未预备根管壁面积百分比显著低于WaveOne Gold和TRUShape,但去除牙本质体积显著更多,三组机械预备时间无显著差异。
要点
- XP-endo Shaper未预备根管壁面积百分比显著低于WaveOne Gold和TRUShape。
- XP-endo Shaper去除牙本质体积显著多于WaveOne Gold和TRUShape。
- 三种系统机械预备时间无显著差异。
核心结论
- 在椭圆形根管中,XP-endo Shaper较WaveOne Gold和TRUShape去除更多牙本质但遗留更少未预备根管壁面积,预备时间相似。
研究设计与样本
- 离体下颌磨牙椭圆形远中根30个,随机分为三组(n=10),采用micro-CT分析。
主要发现
- 未预备根管面积百分比:WaveOne Gold为11.5%±4.0%,TRUShape为12.4%±5.8%,XP-endo Shaper为5.2%±2.6%(p<.05)。
- 去除牙本质体积:XP-endo Shaper为3.3±1.5 mm³,WaveOne Gold为1.8±0.8 mm³,TRUShape为1.9±0.8 mm³(p<.05)。
- 机械预备时间:WaveOne Gold为79±31 s,TRUShape为104±41 s,XP-endo Shaper为71±23 s,组间无显著差异(p>.05)。
临床怎么用
- 对于椭圆形根管,若追求更少未预备根管壁面积,可考虑XP-endo Shaper,但需注意其去除牙本质体积更多。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To compare the shaping ability of a heat-treated centric reciprocating file system (WaveOne Gold), a heat-treated eccentric rotary multifile system (TRUShape 3D Conforming Files), and a heat-treated expandable one-file rotary system (XP-endo Shaper) extending its activation time, in preparing oval-shaped root canals in extracted mandibular molars by means of microcomputed tomography (micro-CT) analysis. METHODOLOGY: Thirty moderately curved oval-shaped distal roots of mandibular molars were selected. The normality of canal length, curvature angle, volume, surface area, structure model index, and aspect ratio were confirmed. The samples were randomly divided into three groups (n = 10). Micro-CT scans were taken before and after canals were instrumented using WaveOne Gold (size 35, .06 taper), or TRUShape (size 30, .06v taper), both following the manufacturer's instructions, or XP-endo Shaper following a new protocol with extended activation time. The mechanical preparation time for each sample was recorded. Pre- and postoperative images were analysed for the percentage of unprepared canal areas and the percentage of removed dentine. Data were compared between groups using the statistical analyses one-way ANOVA and Tukey tests (p < .05). RESULTS: The percentage of unprepared canal areas was significantly higher with WaveOne Gold (% 11.5 ± 4.0) and TRUShape (% 12.4 ± 5.8) compared with XP-endo Shaper (% 5.2 ± 2.6) (p < .05). XP-endo Shaper removed significantly more dentine (3.3 ± 1.5 mm3 ) than WaveOne Gold (1.8 ± 0.8 mm3 ) and TRUShape (1.9 ± 0.8 mm3 ) (p < .05). No significant differences were seen for mechanical preparation time between WaveOne Gold (79 ± 31 s), TRUShape (104 ± 41 s) and XP-endo Shaper (71 ± 23 s) (p > .05). CONCLUSIONS: The comparison of three recognized root canal filing systems has shown that with similar preparation times, the XP-endo Shaper removed more dentine (mm3 ) leaving less unprepared canal wall area (%) than WaveOne Gold and TRUShape when preparing oval-shaped root canals of extracted mandibular molars.
引用
- Poly A, Marques F, Moura Sassone L, et al. The shaping ability of WaveOne Gold, TRUShape and XP-endo Shaper systems in oval-shaped distal canals of mandibular molars: A microcomputed tomographic analysis. Int Endod J. 2021. PMID: 34473842. doi:10.1111/iej.13625
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。