下颌磨牙根管充填54个月后微CT评价充填质量
结果显示54个月后各组空隙比例均下降,热垂直加压组空隙少于单尖法AH Plus组。
要点
- 充填后54个月各组根管充填空隙比例均较1天时下降。
- 热垂直加压配合AH Plus组长期储存后空隙少于单尖法AH Plus组。
- 单尖法配合AH Plus与EndoSequence BC在54个月后无显著差异。
核心结论
- 根管充填后54个月空隙减少,热垂直加压配合AH Plus在长期储存后充填质量优于单尖法配合AH Plus。
研究设计与样本
- 标本储存于37°C、100%湿度,充填后1天和54个月行微CT扫描,采用单因素方差分析和配对t检验分析。
主要发现
- 充填后1天,单尖法配合AH Plus组空隙体积百分比高于单尖法配合EndoSequence BC组和热垂直加压配合AH Plus组(P < .05)。
- 54个月后,所有组空隙比例均下降(P < .05)。
- 54个月后,单尖法配合AH Plus组与单尖法配合EndoSequence BC组间无显著差异。
- 54个月后,热垂直加压配合AH Plus组空隙少于单尖法配合AH Plus组(P < .05)。
临床怎么用
- 下颌磨牙根管充填可考虑热垂直加压配合AH Plus以降低长期空隙。
- 单尖法配合AH Plus或EndoSequence BC长期空隙无显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The present study evaluated the percentage volume of voids in root canals of mandibular molars that had been obturated for 54 months. METHODS: Thirty extracted human mandibular molars were instrumented and debrided. The teeth were assigned to 3 groups (n = 10) according to the filling technique and sealer used: the single-cone technique using AH Plus sealer (AHS; Dentsply Sirona Endodontics, Tulsa, OK) or EndoSequence BC sealer (BCS; Brasseler USA Dental LLC, Savannah, GA) and the warm vertical compaction technique using AH Plus sealer (AHW). The specimens were stored at 37°C and 100% humidity. Micro-computed tomographic imaging was used to scan each specimen 1 day 54 months after obturation. Data were analyzed using 1-way analysis of variance and the paired t test. RESULTS: The percentage volume of voids in the teeth 1 day after obturation in the AHS group was higher than in the BCS group and the AHW group (P < .05). After 54 months, the proportion of voids decreased in all groups (P < .05). No significant difference was observed between the AHS group and the BCS group after 54 months. Teeth in the AHW group contained fewer voids than the AHS group (P < .05). CONCLUSIONS: Voids in root canal filling were reduced 54 months after obturation. The warm vertical compaction technique achieved better root canal filling quality in mandibular molars than the single-cone technique when using AHS after long-term storage at 100% humidity.
引用
- Liu H, Lai WWM, Hieawy A, et al. Micro-computed Tomographic Evaluation of the Quality of Root Canal Fillings in Mandibular Molars after Obturation for 54 Months. J Endod. 2021. PMID: 34492231. doi:10.1016/j.joen.2021.08.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。