文献速递口腔修复与种植

阳极氧化种植体在不同负荷方案下的临床疗效:系统综述与Meta分析

Clinical efficacy of anodized dental implants for implant-supported prostheses after different loading protocols: A systematic review and meta-analysis.
PubMed 文献 · Clin Oral Implants Res · 2021-08-17

本系统综述与Meta分析纳入24项研究(22项定量分析),比较阳极氧化种植体在即刻/早期负荷(IL)与常规负荷(CL)下支持不同修复体的临床效果。总体合并分析显示两组所有结局无显著差异(p > .05),但按修复体类型分层后,CL可降低全牙弓固定修复体的边缘骨吸收(p < .05),IL在覆盖义齿中表现出特定时间点的差异。

要点

  • 总体合并分析中,IL与CL负荷方案在种植体存留率、边缘骨吸收等所有结局上无显著差异(p > .05)。
  • 全牙弓固定修复体亚组中,CL负荷可显著降低边缘骨吸收(p < .05)。
  • 覆盖义齿中IL负荷在12个月时菌斑指数更高,但在≥24个月时边缘骨吸收更低(p < .05)。

核心结论

  • 在研究的局限性内,总体而言即刻/早期负荷与常规负荷方案在阳极氧化种植体的各项结局上无显著差异。

研究设计与样本

  • 系统综述与Meta分析,检索7个数据库,纳入随机对照试验(RCT)和非随机对照临床试验(CCT),最终24项研究符合条件,其中22项纳入定量分析。
  • 比较阳极氧化种植体支持单冠、固定局部义齿(FPD)、全牙弓固定义齿(FDP)或覆盖义齿时,即刻/早期负荷(IL)与常规负荷(CL)的临床效果。
  • 使用Cochrane协作工具评估偏倚风险,对不同随访时间进行Meta分析,并评估异质性来源及采用GRADE方法。

主要发现

  • 多数RCT(58%,n = 11)存在高偏倚风险,所有5项CCT存在严重偏倚风险。
  • 总体合并所有修复体设计,IL与CL方案在所有结局上均无显著差异(p > .05)。
  • 按修复体类型亚组分析:CL可降低全牙弓FDP的边缘骨吸收(p < .05)。
  • 覆盖义齿中,IL在12个月时菌斑指数更高,但在≥24个月时边缘骨吸收更低、3个月时种植体稳定性商数(ISQ)更高、6和12个月时探诊深度(PD)更低(p < .05)。
  • 单冠中,IL在3和6个月时PD更高(p < .05);全牙弓FDP(36个月)和FPD(12和36个月)中,IL的边缘骨吸收平均差更高(p < .05)。

临床怎么用

  • 对于阳极氧化种植体,即刻/早期负荷与常规负荷在总体临床结局上无显著差异,可根据临床情况选择负荷方案。
  • 全牙弓固定修复体选择常规负荷可能有利于减少边缘骨吸收;覆盖义齿选择即刻/早期负荷需关注早期菌斑控制和长期骨吸收。

局限性

  • 多数纳入RCT存在高偏倚风险,所有CCT存在严重偏倚风险,证据质量受限。
  • 研究结论需在本文局限性内解读,亚组分析结果可能受异质性影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To summarize the clinical performance of anodized implants connected to different prostheses design after immediate/early (IL) or conventional loading (CL) protocols. MATERIALS AND METHODS: Seven databases were surveyed for randomized (RCTs) and non-randomized controlled clinical trials (CCTs). Studies comparing IL vs. CL protocol of anodized implants supporting single crown, fixed partial denture (FPD), full-arch fixed dental prosthesis (FDP), or overdenture were included. Risk-of-bias was evaluated using Cochrane Collaboration tools. Meta-analyses for different follow-up were analyzed, followed by heterogeneity source assessment and GRADE approach. The outcomes included implant survival rate, marginal bone loss (MBL), implant stability quotient (ISQ), probing depth (PD), plaque index (PI), and peri-implantitis prevalence. RESULTS: From 24 eligible studies, 22 were included for quantitative evaluation. Most RCTs (58%, n = 11) and all the 5 CCTs had high and serious risk-of-bias, respectively. Overall, pooling all prosthesis design, no difference between IL vs. CL protocols was observed for all outcomes (p > .05). However, according to prosthesis type subgroups, CL reduced MBL for full-arch FDP (p < .05). In a point-in-time assessment, with overdenture, although IL presented higher PI (12 months), it showed lower MBL (≥24 months), higher ISQ (3 months), and lower PD (6 and 12 months) (p < .05). Conversely, PD was higher for IL in single crown (3 and 6 months) (p < .05). Regarding MBL, IL demonstrated higher mean difference for full-arch FDP (36 months) and FPD (12 and 36 months) (p < .05). CONCLUSION: Within the limitations of this study, overall, there is no significant difference in the outcomes between IL and CL loading protocols.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Nagay BE, Dini C, Borges GA, et al. Clinical efficacy of anodized dental implants for implant-supported prostheses after different loading protocols: A systematic review and meta-analysis. Clin Oral Implants Res. 2021. PMID: 34352130. doi:10.1111/clr.13813

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。