牙种植体内部去污染冲洗方案的体外与体内比较研究
本研究比较不同冲洗方案对两段式牙种植体内部空腔去污染的效果。体外部分用40颗种植体龈下细菌接种后比较刷洗加冲洗与单纯冲洗;结果显示10%过氧化氢在体内外均获得最高相对总细菌量减少,加用刷洗无额外获益。
要点
- 10%过氧化氢冲洗在体外和体内均显示最高相对总细菌量减少。
- 加用刷洗对去污染效果无显著增益(p=0.088)。
- 临床中氯己定0.2%的相对总细菌量减少最低(7.1%)。
核心结论
- 含10%过氧化氢的冲洗方案对种植体内部去污染具有潜在优势。
- 过氧化氢在相对总细菌量减少方面优于其他三种冲洗溶液。
研究设计与样本
- 体外部分:80份样本来自40颗接种龈下细菌24小时的种植体,比较刷洗加冲洗与单纯冲洗。
- 采用实时PCR分析总细菌量,比较四种冲洗溶液的相对减少差异。
主要发现
- 体外相对总细菌量减少:过氧化氢87.1%,氯己定56.9%,酒精43.7%,生理盐水42.7%。
- 体内相对总细菌量减少:过氧化氢51.4%,酒精30.4%,生理盐水26.3%,氯己定7.1%。
- 加用刷洗无有益效应(p=0.088)。
关键数值与推荐
- 冲洗溶液包括氯己定0.2%、过氧化氢10%、酒精70%和氯化钠0.9%。
- 过氧化氢在相对总细菌量减少方面优于所有其他冲洗溶液。
临床怎么用
- 可考虑将10%过氧化氢纳入种植体内部去污染的冲洗方案。
- 单纯冲洗即可,无需额外加用刷洗。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Previous investigations have shown a progressive bacterial colonization of the internal cavities of two-piece dental implants with possible implications for peri-implant bone loss. The aim of the study was to compare different irrigation protocols for the internal decontamination of implants in vitro and in vivo. MATERIALS AND METHODS: In the in vitro part, 80 samples were obtained 24 h after inoculation with an aliquot of subgingival bacteria from 40 implants as follows: before and after either cleaning with a brush and an irrigation solution (irrigation-brush-irrigation: test) or repeated irrigation alone (irrigation-irrigation: control). In the clinical study, 40 samples from twenty partially edentulous patients contributing each with one implant were collected after removal of abutment and suprastructure with sterile paper points immediately before and after decontamination and subsequently analyzed for total bacterial counts (TBC) by real-time-PCR. Irrigation solutions were chlorhexidine (0.2% (CHX)), H2 O2 (10%), alcohol (70%, (ALC)), and NaCl (0.9%). Differences in proportional reduction of TBC between the four irrigation solutions were analyzed. RESULTS: Irrigation with H2 O2 showed the highest effect in both parts of the study (relative TBC reduction in vitro: H2 O2 : 87.1%, CHX: 56.9%, ALC: 43.7%, NaCl: 42.7%; in vivo: H2 O2 : 51.4%, ALC: 30.4%, NaCl: 26.3%, CHX: 7.1%). The additional use of a brush showed no beneficial effect (p = 0.088). Overall, H2 O2 was superior to all other irrigation solutions with regard to relative TBC reduction. CONCLUSIONS: The present results indicate the potential of an irrigation protocol that includes a 10% H2 O2 solution for the internal decontamination of implants. (ClinicalTrials.gov NCT01917305).
引用
- Jervøe-Storm PM, Hablützel AS, Bartels P, et al. Comparison of irrigation protocols for the internal decontamination of dental implants-results of in vitro and in vivo studies. Clin Oral Implants Res. 2021. PMID: 34352143. doi:10.1111/clr.13814
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。