文献速递口腔修复与种植

种植体几何形状与备洞设计对早期骨愈合的影响:临床前体内研究

Influence of implant geometry and osteotomy design on early bone healing: A pre-clinical in vivo study.
PubMed 文献 · Clin Oral Implants Res · 2021-08-14

该临床前犬模型研究比较了两种种植体几何形状与常规或改良(缩小直径)备洞方案组合后的早期骨结合表现。改良备洞产生更高植入扭矩,植入扭矩与愈合6周后影像学骨丢失相关;Test-2位点ISQ下降更明显,且中根尖区BIC%显著高于Test-1。提示 undersized 备洞会加剧早期皮质骨改建。

要点

  • 改良(缩小直径)备洞方案产生更高的植入扭矩。
  • 植入扭矩与愈合6周后影像学骨丢失存在相关性。
  • Test-2位点愈合期ISQ下降较其他位点更明显。

核心结论

  • 在缩小直径的备洞位点植入种植体,会导致早期愈合过程中皮质骨改建增加。

研究设计与样本

  • 在六只犬下颌前磨牙/磨牙区拔牙后,采用常规或改良(缩小直径)备洞方案植入两种种植体。
  • 设置三个位点类别:Reference(A种植体+常规备洞)、Test-1(B种植体+常规备洞)、Test-2(B种植体+改良备洞)。
  • 种植体植入程序在4周和6周后重复,第三次植入后立即取活检进行组织学分析。

主要发现

  • 改良备洞方案产生更高的植入扭矩(ITQ)。
  • 分析显示植入时植入扭矩与愈合6周后影像学骨丢失之间存在相关性。
  • 愈合期间ISQ值下降在Test-2位点较其他位点更明显。
  • 愈合6周时边际区骨-种植体接触率(BIC%)在测试位点与参考位点相似。
  • Test-2种植体在中部和根尖区的BIC%显著高于Test-1种植体。

临床怎么用

  • 临床采用缩小直径备洞时需关注早期皮质骨改建增加及ISQ下降更明显的可能。

局限性

  • 研究为犬模型临床前体内研究,样本量为六只犬,外推至临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To analyze the early stages of osseointegration around implants with different geometry following installation in sites using different osteotomy protocols. MATERIALS AND METHODS: Two types of implants were installed using regular or modified (reduced diameter) osteotomy protocols in mandibular premolar/molar regions following tooth extraction in six dogs. Three implant site categories were created: Reference (A implant and regular osteotomy), Test-1 (B implant and regular osteotomy), and Test-2 (B implant and modified osteotomy). Implant installation procedures were repeated after 4 and 6 weeks. The insertion torque (ITQ) was measured during implant installation and resonance frequency analysis providing implant stability quotient (ISQ) values was performed following implant installation and once every week during the course of the study. Biopsies were obtained immediately after the 3rd installation procedure and prepared for histological analysis. RESULTS: The modified osteotomy protocol created a higher insertion torque (ITQ). The analysis also revealed a correlation between insertion torque at implant installation and radiographic bone loss after 6 weeks of healing. The decline in ISQ values during healing was more pronounced at Test-2 than other sites. While the degree of bone-to-implant contact (BIC%) in the marginal area was similar in test and reference sites at 6 weeks of healing, Test-2 implants presented with a significantly higher BIC% in the mid and apical areas than Test-1 implants. CONCLUSIONS: It is suggested that placement of implants in undersized osteotomy sites will result in an increased remodeling of the cortical bone during the early healing process.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Abrahamsson I, Carcuac O, Berglundh T, et al. Influence of implant geometry and osteotomy design on early bone healing: A pre-clinical in vivo study. Clin Oral Implants Res. 2021. PMID: 34352142. doi:10.1111/clr.13816

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。