文献速递牙体牙髓病

基于CBCT与Micro-CT参数化模型的下颌磨牙根管工作宽度自动测量方法

An Automated Measurement Method for the Endodontic Working Width of Lower Molars by Means of Parametric Models Using Cone-beam Computed Tomographcy and Micro-Computed Tomography.
PubMed 文献 · J Endod · 2021-08-14

本研究提出一种利用CBCT或Micro-CT影像近似根管横截面形状和工作宽度的新方法,对29颗离体下颌第一、第二磨牙远中根管进行三维重建和切片分析,采用不同二维参数化模型拟合根管轮廓。结果显示CBCT测量的根管小径和大径均显著高于Micro-CT(P < .05),两者从根尖孔开始均增大(P < .01),根尖区最窄宽度CBCT为0.19-0.24 mm、Micro-CT为0.09-0.21 mm,颈部三分之一最大锥度为13%-17%。

要点

  • CBCT测量的根管宽度显著大于Micro-CT,临床评估根尖直径时需考虑模态差异。
  • 根管最窄宽度位于根尖区,CBCT为0.19-0.24 mm,Micro-CT为0.09-0.21 mm。
  • 颈部三分之一根管锥度最大值为13%-17%,可用于指导预备锥度选择。

核心结论

  • CBCT和Micro-CT三维影像可对根管横截面工作宽度进行解剖学评估,有助于确定合适根尖直径及颈部和中部正确锥度。

研究设计与样本

  • 采用29颗离体下颌第一和第二磨牙远中根管(未预备)的扫描数据,用自主研发测量算法重建分析。
  • 三维体积模型垂直于垂直轴切片,用不同二维参数化模型近似每个根管切片轮廓以确定横截面尺寸。
  • 对根管小径、大径和锥度进行方差分析。

主要发现

  • CBCT图像评估的根管小径和大径显著高于Micro-CT数据(P < .05)。
  • 根管小径和大径均从根尖孔开始增大(P < .01)。
  • 根尖区最窄测量宽度:CBCT为0.19-0.24 mm,Micro-CT为0.09-0.21 mm。
  • 颈部三分之一最大锥度值为13%-17%。

临床怎么用

  • 临床可借助CBCT或Micro-CT三维数据评估根管横截面工作宽度,辅助确定根尖直径和预备锥度。
  • 注意CBCT测量的根管宽度可能高于Micro-CT,解读根尖直径时应考虑成像模态差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: A new method for the approximation of the root canal's cross-sectional shape and its working width using cone-beam computed tomographic (CBCT) or micro-computed tomographic (micro-CT) imaging was introduced. METHODS: Scanned data from 29 extracted human mandibular first and second molar distal root canals without instrumentation were reconstructed and analyzed with a self-developed measurement algorithm. The 3-dimensional volume models were sliced perpendicular to the vertical axis. Using different 2-dimensional parametric models, the contour of each root canal slice was approximated and used to determine the canal's cross-sectional dimensions. The measurements of minor width, major width, and the root canal's conicity were statistically analyzed using analysis of variance. RESULTS: The measured minor and major widths of the investigated root canals were significantly higher (probability value P < .05) when evaluated by CBCT images than the results obtained from micro-CT data. Both dimensions increased starting from the apical foramen (P < .01). The narrowest measured canal widths were 0.19-0.24 mm for CBCT imaging and 0.09-0.21 mm for micro-CT imaging in the apical part. The maximum values for conicity were between 13% and 17% in the cervical third. CONCLUSIONS: The 3-dimensional imaging data from CBCT and micro-CT imaging enabled a valuable anatomic assessment of the root canal's cross-sectional working width along the canal up to the physiological foramen in order to determine an adequate apical diameter as well as the correct measured taper in the cervical and medial part.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Kucher M, Dannemann M, Modler N, et al. An Automated Measurement Method for the Endodontic Working Width of Lower Molars by Means of Parametric Models Using Cone-beam Computed Tomographcy and Micro-Computed Tomography. J Endod. 2021. PMID: 34400197. doi:10.1016/j.joen.2021.08.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。