载药二氧化硅共组装颗粒根管封闭剂的体外抗菌评估
本研究在粪肠球菌感染的根管牙本质模型上,评估载有高载药二氧化硅共组装颗粒(DSPs)的两种根管封闭剂的抗菌活性。DSPs由二氧化硅与奥替尼啶二盐酸盐(OCT)共组装而成(含35% w/w OCT),以1%质量分数分别加入环氧树脂类AH Plus和硅酸钙类BC Sealer。结果显示,载DSPs的BC Sealer在所有时间点均显著降低菌落形成单位,而AH Plus仅在1天时抗菌性能增强。
要点
- 载DSPs的BC Sealer在1、7、28天均显著降低粪肠球菌CFU。
- 载DSPs的AH Plus仅在1天时增强抗菌活性。
- AH与AH+DSPs组细菌存活率在各时间点均高于BC与BC+DSPs组。
核心结论
- DSPs对根管封闭剂抗菌性能的影响具有材料依赖性,可能减少继发感染的发生。
研究设计与样本
- 体外研究:将DSPs(含35% w/w OCT,占封闭剂总质量1%)分别混入AH Plus或BC Sealer。
- 使用单根牙根尖三分之一段,粪肠球菌感染3周后应用实验封闭剂或对照,观察至28天。
主要发现
- 所有实验组在所有时间点CFU均显著低于阳性对照(P < .05)。
- BC+DSPs组在1、7、28天CFU分别为2.11 ± 0.13、2.22 ± 0.19、2.25 ± 0.17,低于未改性BC组的3.21 ± 0.11、4.3 ± 0.15、4.2 ± 0.2。
- AH+DSPs组仅在1天时CFU低于未改性AH组(4.21 ± 0.17 vs 5.19 ± 0.12,P < .05)。
- AH与AH+DSPs组在所有孵育期的细菌存活率均高于BC与BC+DSPs组(P < .05)。
临床怎么用
- 硅酸钙类封闭剂载DSPs可能获得更持久的抗菌效果。
- 环氧树脂类封闭剂载DSPs的抗菌增强有限,需结合材料选择评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to assess the antimicrobial activity of root canal sealers modified with novel highly loaded antimicrobial drug-silica coassembled particles (DSPs) on Enterococcus faecalis-infected root canal dentin. METHODS: DSPs were synthesized through coassembly of silica and octenidine dihydrochloride (OCT) surfactant drug (35% w/w OCT). DSPs (1% wt of the total mass of the sealer) were mixed homogenously with either epoxy resin sealer (AH Plus [AH]; Dentsply Sirona, Tulsa, OK) or calcium silicate-based sealer (EndoSequence BC Sealer [BC]; Brasseler, Savannah, GA). To assess the antimicrobial activity of DSP-loaded sealers, the apical third of single-rooted teeth was obtained and infected with E. faecalis for 3 weeks followed by the application of experimental (DSP-loaded) sealers or corresponding controls for up to 28 days. Microbiological analysis and laser scanning confocal and scanning electron microscopy were used to determine the colony-forming unit (CFU)/mL, the percentage of live bacteria, and the intratubular bacterial and sealer penetrations. Factorial analysis of variance and Tukey post hoc tests were used to assess the antimicrobial effect of DSPs on different sealers. RESULTS: All experimental groups showed significant reductions in CFUs at all-time points compared with positive controls (P < .05). The addition of DSPs to BC significantly reduced the CFUs (2.11 ± 0.13, 2.22 ± 0.19, and 2.25 ± 0.17 at 1, 7, and 28 days, respectively) compared with the unmodified sealer (3.21 ± 0.11, 4.3 ± 0.15, and 4.2 ± 0.2 at 0, 7, and 28 days). DSPs enhanced the antimicrobial performance of AH only at 1 day (4.21 ± 0.17 vs 5.19 ± 0.12, P < .05). AH and AH + DSPs showed higher bacterial viability compared with BC and BC + DSPs at all incubation periods (P < .05). CONCLUSIONS: Loading endodontic sealers with DSPs had a material-dependent effect on the antimicrobial properties and could reduce the incidence of secondary infections.
引用
- Marashdeh MQ, Stewart CA, Kishen A, et al. Assessment of Root Canal Sealers Loaded with Drug-Silica Coassembled Particles Using an In Vitro Tooth Model. J Endod. 2021. PMID: 34425150. doi:10.1016/j.joen.2021.08.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。