低剂量锥形束CT在计算机引导种植中的可预测性与图像质量:一项实验研究
本研究以猪下颌骨尸体为对象,对比低剂量与高清锥形束CT在计算机引导种植中的表现。结果显示低剂量CBCT在种植体根尖和角度偏差上大于高清CBCT,但入口点偏差无显著差异,图像质量略低,提示低剂量CBCT可作为替代方案但需权衡辐射剂量。
要点
- 低剂量CBCT种植体根尖平均偏差3.0±1.2 mm,大于高清CBCT的2.3±1.1 mm。
- 低剂量CBCT角度平均偏差13.2±6.3°,大于高清CBCT的9.2±5.3°。
- 低剂量CBCT图像质量评分2.5±0.6,略低于高清CBCT的2.7±0.6。
核心结论
- 在部分引导种植中,低剂量CBCT可作为高清CBCT的替代方案,但高清CBCT的优势需与更高辐射剂量权衡。
主要发现
- 种植体根尖平均偏差:低剂量CBCT 3.0±1.2 mm,高清CBCT 2.3±1.1 mm。
- 入口点平均偏差:低剂量CBCT 1.4±0.9 mm,高清CBCT 1.7±0.6 mm,未见明显差异。
- 角度平均偏差:低剂量CBCT 13.2±6.3°,高清CBCT 9.2±5.3°。
- 图像质量平均评分:高清CBCT 2.7±0.6,低剂量CBCT 2.5±0.6。
临床怎么用
- 在部分引导种植中可考虑使用低剂量CBCT以减少辐射,但需接受根尖和角度偏差增大的风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate the predictability and image quality of low-dose cone-beam computed tomography (LD-CBCT) in computer-guided implantology. METHODS: Pig cadaver mandibles were imaged using high-definition CBCT (HD-CBCT) and LD-CBCT (HD-CBCT: 85 kV, 6 mA, 14.2 s, 767 frames, 1184 mGycm2, voxel size 80 µm, effective dose 231 µSv; LD-CBCT: 85 kV, 10 mA, 2.1 s, 384 frames, 84 mGycm2, voxel size 160 µm, effective dose 16 µSv; Orthophos SL, Dentsply Sirona, Bensheim, Germany). Digital impressions were taken using intraoral scanning (IOS; Omnicam, Dentsply Sirona). Data of CBCT modalities and IOS were aligned. Forty-eight implants were planned virtually (24 implants per modality; Bone Level 4.1 × 10 mm; Straumann AG, Basel, Switzerland). Implants were inserted using templates by initial pilot drilling ("partially-guided implantation"). Implant positions were recorded using IOS. Geometric deviations between planned and definitive positions were assessed regarding implant apex, entry-point and angle. CBCT image quality was evaluated by raters twice on a four point scale. The results were exploratively compared (linear models, Mann-Whitney-U tests). RESULTS: Regarding implant apex, deviations were greater for LD-CBCT (mean 3.0±1.2 mm), as compared to HD-CBCT (mean 2.3±1.1 mm). For entry-point, no distinct difference was detected with a mean deviation of 1.4±0.9 mm in LD-CBCT, and 1.7±0.6 mm in HD-CBCT. Regarding angle, deviations were greater for LD-CBCT (mean 13.2±6.3°), as compared to HD-CBCT (mean 9.2±5.3°). The image quality of HD-CBCT provided to be better (mean 2.7±0.6) than that of LD-CBCT (mean 2.5±0.6). CONCLUSIONS: Within the partially-guided approach, the results underline the potential of LD-CBCT alternatively to HD-CBCT for computer-guided implantology. Advantages of HD-CBCT need to be balanced against the higher radiation dose.
引用
- Horsch L, Labis C, Trebing CT, et al. Predictability and image quality of low-dose cone-beam computed tomography in computer-guided implantology: An experimental study. J Dent. 2021. PMID: 34252488. doi:10.1016/j.jdent.2021.103744
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。