多孔钛结构对骨质疏松种植体骨传导性的影响
本研究在4只卵巢切除诱导骨质疏松的比格犬下颌骨植入30枚种植体,评估表面多孔钛结构(PS)对骨结合的影响。结果显示PS组根尖区螺纹间骨面积显著增加(P=0.028),组织学可见骨长入孔隙,提示PS可改善骨质疏松骨中的骨传导性。
要点
- PS组根尖区螺纹间骨面积显著大于对照组(P=0.028)。
- 组织学显示PS孔隙内有骨长入,表明骨传导性改善。
- 两组共振频率分析和移除扭矩值在4周时无显著差异。
核心结论
- 表面多孔钛结构可通过骨长入孔隙改善骨质疏松骨中的骨传导性,从而增强种植体的骨结合与稳定性。
研究设计与样本
- 4只雌性比格犬行双侧卵巢切除术诱导骨质疏松32周,下颌后牙拔除后植入30枚种植体(每组15枚)。
主要发现
- 卵巢切除32周后下颌骨小梁、腰椎和股骨头HU值显著下降,确认骨质疏松模型成功。
- 种植后4周两组共振频率分析和移除扭矩值相当。
- PS组根尖区螺纹间骨面积显著大于对照组(对照组:0.059 ± 0.041 mm²,试验组:0.121 ± 0.060 mm²,P = 0.028)。
- 组织学显示PS组根尖区有骨长入孔隙,骨-种植体接触长度在PS组根尖区更大但无统计学显著性。
关键数值与推荐
- 骨质疏松诱导成功标准为CT图像Hounsfield单位评估的骨密度下降。
- 对照组种植体采用可吸收喷砂介质(RBM)表面处理,试验组冠方2/3行RBM处理、根尖3 mm部分添加PS。
临床怎么用
- 对于骨质疏松患者,可考虑在种植体根尖部分采用多孔钛结构以增强骨传导和稳定性。
局限性
- 样本量小(4只动物,30枚种植体),观察期仅4周,需进一步长期和临床研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
In compromised bone conditions such as osteoporosis, developments of the implant surface are necessary to secure the stability of implants. This study investigated the effect of the surface porous titanium structure (PS) on the osseointegration of implants in osteoporotic bone. Bilateral ovariectomy (OVX) was performed in 4 female beagle dogs to induce osteoporosis for 32 wk. Success of induction was based on the evaluation of bone mineral density by Hounsfield units (HU) in computed tomography images. Posterior teeth in both mandibles were extracted 1 wk after OVX, and a total of 30 implants (15 implants in each group) were placed after 32 wk of osteoporosis induction. The control group implant underwent resorbable blast media (RBM) surface treatment, whereas the test group underwent RBM surface treatment in the coronal two-thirds and a PS added to the apical 3-mm portion. HU values in the mandibular trabecular bone, lumbar, and femoral head significantly decreased 32 wk after OVX, confirming osteoporotic condition after induction. Resonance frequency analysis and removal torque test showed comparable values between the 2 groups at 4 wk after implant placement. The surface topography of the implant after removal showed hard tissue integration at the PS in the test group. Bone-to-implant contact length was greater in the apical portion of the test group, although statistical significance was not found between the groups. Interthread bone area in the apical portion of the test group showed a significant increase compared to the control group (control: 0.059 ± 0.041 mm2, test: 0.121 ± 0.060 mm2, P = 0.028) with the histological feature of bone ingrowth at the PS. The findings of the study demonstrated that the surface PS could improve osteoconductivity in the osteoporotic trabecular bone by bone ingrowth at the pore space, thereby enhancing the osseointegration and stability of the implants.
引用
- Ko SY, Hong JY, Lee W, et al. Osteoconductivity of Porous Titanium Structure on Implants in Osteoporosis. J Dent Res. 2021. PMID: 34235985. doi:10.1177/00220345211023724
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。