文献速递牙体牙髓病

马卡罗尔三联抗生素糊剂与氢氧化钙及蜂胶乙醇提取物体外抗菌效果比较

Antibacterial Efficacy of Triple Antibiotic Medication With Macrogol (3Mix-MP), Traditional Triple Antibiotic Paste, Calcium Hydroxide, and Ethanol Extract of Propolis: An Intratubular Dentin Ex Vivo Confocal Laser Scanning Microscopic Study.
PubMed 文献 · J Endod · 2021-07-24

3Mix-MP与m3Mix-MP抗菌效果显著优于其他药物(除mTAP外),mTAP优于TAP,EEP与CH不劣于TAP和mTAP。结论提示高浓度3Mix-MP并不优于指南推荐浓度的mTAP。

要点

  • 3Mix-MP与m3Mix-MP抗菌效果显著优于除mTAP外的其他药物。
  • mTAP抗菌效果显著优于传统TAP。
  • EEP与CH的抗菌效果与TAP和mTAP无显著差异。

核心结论

  • 含极高浓度抗生素(1500 mg/mL)的3Mix-MP和m3Mix-MP并不优于美国牙髓病医师协会推荐浓度(5 mg/mL)的mTAP。
  • 氢氧化钙和蜂胶乙醇提取物的抗菌效果与TAP和mTAP相当。

研究设计与样本

  • 设1个对照组及TAP、mTAP、3Mix-MP、m3Mix-MP、CH、EEP实验组,封药14天后用激光共聚焦扫描显微镜定量活菌百分比。

主要发现

  • 3Mix-MP和m3Mix-MP的抗菌效果显著高于其他受试药物(P < .05),但mTAP除外。
  • mTAP的抗菌效果显著优于TAP(P < .05)。
  • EEP和CH的抗菌效果与TAP和mTAP无显著差异(P > .05)。
  • 所有药物与对照组相比均显示有效抗菌作用(P < .05)。

关键数值与推荐

  • 3Mix-MP和m3Mix-MP的抗生素浓度为1500 mg/mL。
  • 美国牙髓病医师协会推荐的mTAP浓度为5 mg/mL。
  • 统计学显著性水平设为P < .05。

临床怎么用

  • 在再生牙髓治疗选药时,可考虑指南推荐浓度的mTAP而非极高浓度3Mix-MP。
  • 氢氧化钙或蜂胶乙醇提取物可作为TAP/mTAP的替代抗菌药物选项。

局限性

  • 研究为离体牙本质小管实验,结果不能直接外推至临床疗效。
  • 样本仅使用粪肠球菌单一菌种污染,未反映多菌种感染环境。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study aimed to assess the effectiveness of antibacterial activity of medications used in regenerative endodontic treatment. METHODS: Sixty-seven dentin cylinders of single-rooted teeth were contaminated with a culture of Enterococcus faecalis (ATCC 29212; American Type Culture Collection, Manassas, VA) for 5 days. Samples were divided into 1 control group and the following experimental groups according to the medication applied: traditional triple antibiotic paste (TAP), clindamycin-modified TAP (mTAP), triple antibiotic medication with macrogol (3Mix-MP), clindamycin-modified 3Mix-MP (m3Mix-MP), calcium hydroxide (CH), and ethanol extract of propolis (EEP). After 14 days, the medications were removed, and the samples were submitted to confocal laser scanning microscopic analysis to quantify the percentage of viable bacteria. The distribution of data was confirmed by the Shapiro-Wilk test. The Kruskal-Wallis and Dunn tests were used for intergroup comparisons, and the Wilcoxon test was used for comparison between superficial and deep antibacterial efficacy for the same medication. The level of significance was set at P < .05. RESULTS: 3Mix-MP and m3Mix-MP presented significantly higher antibacterial efficacy compared with the other tested medications (P < .05), except for mTAP. mTAP was more effective than TAP (P < .05). The antibacterial efficacy of EEP and CH did not differ significantly from TAP and mTAP (P > .05). All medications showed effective antibacterial action compared with the control group (P < .05). CONCLUSIONS: 3Mix-MP and m3Mix-MP, which present extremely high concentrations of antibiotics (1500 mg/mL), were not more effective than mTAP at the concentration recommended by the American Association of Endodontists (5 mg/mL). Moreover, CH and EEP were as effective as TAP and mTAP.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Cunha Neto MAD, Coêlho JA, Pinto KP, et al. Antibacterial Efficacy of Triple Antibiotic Medication With Macrogol (3Mix-MP), Traditional Triple Antibiotic Paste, Calcium Hydroxide, and Ethanol Extract of Propolis: An Intratubular Dentin Ex Vivo Confocal Laser Scanning Microscopic Study. J Endod. 2021. PMID: 34310981. doi:10.1016/j.joen.2021.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。