三维动态导航系统拔除根管治疗牙纤维桩的精度与效率
本研究在离体上颌牙模型中比较三维动态导航系统(DNS)与自由手技术(FH)拔除纤维桩的精度与效率,每组13颗牙。结果显示DNS组在冠根向偏移、角度偏斜、操作时间及牙体组织体积损失上均显著优于FH组(P < .05)。
要点
- DNS拔除纤维桩的冠根向偏移和角度偏斜显著小于自由手技术。
- DNS操作时间更短,且牙体组织体积损失显著更少。
- 在离体牙模型中,DNS辅助拔桩的精度和效率均优于自由手。
核心结论
- DNS在拔除根管治疗牙纤维桩方面比自由手技术更精确、更高效。
研究设计与样本
- 术前术后拍摄锥形束CT,比较冠根向偏移、角度偏斜、操作时间、失误次数及牙体体积损失。
主要发现
- DNS组的冠向和根向全局偏移及角度偏斜均显著小于FH组(P < .05)。
- DNS组操作时间少于FH组。
- DNS组牙体组织体积损失显著少于FH组(P < .05)。
临床怎么用
- 临床拔除根管治疗牙纤维桩时,可考虑使用三维动态导航系统以提高精度和效率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The purpose of this study was to investigate the accuracy and efficiency of the 3-dimensional dynamic navigation system (DNS) compared with the freehand technique (FH) when removing fiber posts from root canal-treated teeth. METHODS: Twenty-six maxillary teeth were included. Teeth were root canal treated and restored with Parapost Taper Lux (Coltene/Whaledent, Altstätten, Switzerland) luted with RelyX Unicem (3M ESPE, St Paul, MN). A core buildup was then performed using Paracore (Coltene/Whaledent). Teeth were mounted in tissue-denuded cadaver maxillae. Teeth were divided into 2 groups: the DNS group (n = 13) and the FH group (n = 13). Cone-beam computed tomographic scans were taken pre- and postoperatively. The drilling path and depth were planned virtually using X-guide software (X-Nav Technologies, Lansdale, PA) in both groups. For the DNS group, drilling was guided with X-Nav software and the FH group under a dental operating microscope. Global coronal and apical deviations, angular deflection, operation time, and the number of mishaps were compared between the groups to determine the accuracy and efficiency. The 3-dimensional volume (mm3) of all teeth was calculated before and after post removal using the Mimics Innovation Suite (Materialise NV, Leuven, Belgium). The Shapiro-Wilk, 1-way analysis of variance, and Fisher exact tests were used (P < .05). RESULTS: The DNS group showed significantly less global coronal and apical deviations and angular deflection than the FH group (P < .05). DNS required less operation time than FH. Moreover, the DNS technique had significantly less volumetric loss of tooth structure than the FH technique (P < .05). CONCLUSIONS: The DNS was more accurate and efficient in removing fiber posts from root canal-treated teeth than the FH technique.
引用
- Janabi A, Tordik PA, Griffin IL, et al. Accuracy and Efficiency of 3-dimensional Dynamic Navigation System for Removal of Fiber Post from Root Canal-Treated Teeth. J Endod. 2021. PMID: 34265326. doi:10.1016/j.joen.2021.07.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。