分块Le Fort I截骨术规划与随访的三维评估:一项验证研究
本研究开发并验证了一种基于体素配准的三维半自动评估方案,用于评价分块Le Fort I截骨术的规划精确度与短期稳定性。研究纳入20例患者(13女7男),利用术前、术后即刻及术后6个月CBCT评估各上颌骨块的三维平移与旋转。结果显示观察者间与观察者内ICC为0.93–0.99,平移MAD为0.21–0.32 mm,旋转MAD为0.6°–0.9°。
要点
- 三维半自动体素配准评估分块Le Fort I截骨规划精确度与稳定性具有高可靠性。
- 观察者间与观察者内ICC为0.93–0.99,平移MAD为0.21–0.32 mm,旋转MAD为0.6°–0.9°。
- 该方案可用于未来深入分析分块Le Fort I截骨术并在必要时改进。
核心结论
- 分块Le Fort I截骨规划精确度与短期随访的三维评估方案具有高可靠性,误差幅度小。
研究设计与样本
- 开发并验证基于体素配准的三维半自动评估方案,纳入20例(13女7男)行分块Le Fort I截骨术患者,使用术前、术后即刻及术后6个月CBCT评估各上颌骨块。
主要发现
- 观察者间与观察者内ICC在平移和旋转精确度与稳定性评估中为0.93–0.99,表明可靠性极好。
- 平移误差的MAD为0.21–0.32 mm,旋转维度的MAD为0.6°–0.9°。
关键数值与推荐
- 每个上颌骨块计算三个平移维度(左/右、压入/伸出、前/后)和三个旋转维度(俯仰、翻滚、偏航)。
- 观察者间与观察者内ICC为0.93–0.99,平移MAD为0.21–0.32 mm,旋转MAD为0.6°–0.9°。
临床怎么用
- 该三维评估方案可用于分块Le Fort I截骨术的规划精确度与短期稳定性评估,并可能在未来根据需要改进。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The planning accuracy and stability during follow-up of segmented Le Fort I osteotomy, often evaluated using 2D cephalometry and dental cast analysis, is controversial. The aim of this study is to develop and validate a 3D semi-automatic, voxel-based registration assessment protocol to evaluate planning accuracy and stability of segmented Le Fort I osteotomy with individualization of the maxillary segments. METHODS: Preoperative, immediate postoperative and six months postoperative CBCT images were used to evaluate accuracy and stability of the individual segments in 20 patients (13 female; 7 male) who underwent segmented Le Fort I osteotomy. Three translational (left/right, intrusion/extrusion, anterior/posterior) and three rotational (pitch, roll, yaw) dimensions were calculated for each maxillary segment by means of a user-friendly module. Inter- and intra-observer Inter Class Coefficient (ICC) and mean absolute difference (MAD) were calculated. RESULTS: The inter- and intra-observer reliability ICC varied between 0.93 and 0.99 for the translational and rotational accuracy and stability assessments, indicating excellent reliability. The MAD ranged between 0.21 mm and 0.32 mm for the translational error and between 0.6° and 0.9° for the rotational dimension. CONCLUSIONS: The 3D assessment protocol for accuracy of segmented Le Fort I planning and short-term follow-up, proved to have high reliability with only a small margin of error. CLINICAL SIGNIFICANCE: The proposed 3D assessment protocol allows future in-depth analysis of segmented Le Fort I osteotomy and might implicate future improvement where necessary.
引用
- da Costa Senior O, Vaes L, Mulier D, et al. Three dimensional assessment of segmented Le Fort I osteotomy planning and follow-up: A validation study. J Dent. 2021. PMID: 34077799. doi:10.1016/j.jdent.2021.103707
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。