三种根管冲洗针在微预备弯曲根管中的计算流体力学研究
本研究用微CT重建人下颌磨牙弯曲根管,预备至20、25、30号/.06锥度,用计算流体力学模拟30-G开口针及30-G、31-G闭口针在0.05与0.15 mL/s流速下的冲洗液流。结果显示20与25号根管冲洗液无法到达工作长度,30号时特定针与流速组合可达工作长度但各有局限,提示微预备根管注射器冲洗效果受限。
要点
- 20或25/.06锥度根管中冲洗液无法到达工作长度
- 30-G开口针低流速在30号根管可达工作长度但壁面剪切应力很低
- 31-G闭口针高流速在30号根管可达工作长度且剪切应力较高但根尖压力也更高
核心结论
- 使用30-G和31-G针的注射器冲洗在微预备根管中效果受限。
研究设计与样本
- 通过微计算机断层扫描获取2个匹配的人下颌磨牙弯曲近中根管图像,分别预备至20、25、30号/.06锥度。
- 采用计算流体力学模型模拟30-G开口针及30-G、31-G闭口针在0.05和0.15 mL/s流速下的冲洗液流。
主要发现
- 预备至20或25/.06锥度的根管中冲洗液无法到达工作长度。
- 30-G开口针联合低流速在30/.06锥度根管中使冲洗液到达工作长度且根尖压力相对较低,但壁面剪切应力很低。
- 31-G闭口针联合高流速也在30号根管中将冲洗液送达工作长度并产生较高壁面剪切应力,但根尖压力也更高。
临床怎么用
- 对微预备(20或25/.06锥度)的弯曲根管,单纯注射器冲洗可能无法达到工作长度,需考虑辅助冲洗策略。
- 若在30/.06锥度根管使用30-G开口针低流速冲洗,需注意壁面剪切应力很低可能影响清洁效果。
- 若使用31-G闭口针高流速冲洗,虽剪切应力较高但根尖压力也更高,需权衡压力风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to compare the irrigant flow in curved root canals prepared to various apical sizes by constant-taper or variable-taper instruments during syringe irrigation with 3 endodontic needles at 2 different flow rates. METHODS: Two matched curved mesial root canals of human mandibular molars were imaged by micro-computed tomographic imaging after preparation to apical size 20, 25, and 30/.06 taper either by constant-taper or variable-taper instruments. A Computational Fluid Dynamics model was used to simulate the irrigant flow in the 2 root canals prepared to each apical size during syringe irrigation with a 30-G open-ended needle and 30-G and 31-G closed-ended needles at 0.05 and 0.15 mL/s. RESULTS: The irrigant could not penetrate up to the working length in root canals prepared to apical size 20 or 25/.06 taper. The 30-G open-ended needle combined with the low flow rate allowed the irrigant to reach the working length in size 30/.06 taper root canals while maintaining a relatively low apical pressure, but the wall shear stress was very low. The 31-G closed-ended needle combined with the high flow rate also delivered the irrigant to the working length in size 30 root canals and developed higher wall shear stress, but the apical pressure was also higher. CONCLUSIONS: Syringe irrigation using 30-G and 31-G needles was compromised in minimally shaped root canals.
引用
- Boutsioukis C, Gutierrez Nova P. Syringe Irrigation in Minimally Shaped Root Canals Using 3 Endodontic Needles: A Computational Fluid Dynamics Study. J Endod. 2021. PMID: 34118256. doi:10.1016/j.joen.2021.06.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。