文献速递牙体牙髓病

XP-endo器械去除下颌磨牙54个月根管充填物的效果

Efficacy of XP-endo instruments in removing 54 month-aged root canal filling material from mandibular molars.
PubMed 文献 · J Dent · 2021-06-25

研究评估XP-endo Shaper(XPS)与XP-endo Finisher R(XPFR)去除根管治疗后下颌磨牙陈旧充填物的效果。

要点

  • XPS去除BCS与AHS组充填物多于AHW组(P<0.05)
  • XPFR补充后各组剩余充填物比例均显著下降(P<0.05)
  • AHW组根尖区陈旧充填物去除仍令人担忧

核心结论

  • XPS与XPFR联合使用可去除下颌磨牙大部分陈旧根管充填物。
  • 热垂直加压充填的根尖关键区充填物去除仍存挑战。

研究设计与样本

  • 标本在100%湿度、37°C储存54个月后,用XPS与XPFR再治疗,并于三个时间点行微计算机断层扫描。

主要发现

  • XPS在BCS和AHS组去除的充填物多于AHW组(P<0.05)。
  • XPFR补充器械后,所有组剩余充填物比例显著下降(P<0.05)。
  • XPFR在BCS组去除充填物的效率高于AHS或AHW组(P<0.05)。
  • XPS与XPFR联合使用在BCS组去除充填物效率最高,其次为AHS组和AHW组(P<0.05)。

临床怎么用

  • 对根管充填物陈旧的病例,可考虑XPS联合XPFR去除大部分充填物。
  • 热垂直加压充填的病例,根尖区充填物去除需谨慎评估,可能需额外策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the effectiveness of XP-endo Shaper (XPS) and XP-endo Finisher R (XPFR) instruments in removing aged root filling material from root-treated mandibular molars. METHODS: Thirty mandibular molars were instrumented and divided into three groups: single-cone obturation using AH Plus sealer (AHS) or EndoSequence BC sealer (BCS), and warm vertical compaction using AH Plus sealer (AHW). The specimens were stored at 100% humidity and 37 °C for 54 months. Retreatment was performed using XPS and XPFR. Micro-computed tomography was used to scan the specimens after 54 months, after XPS retreatment and after the supplementary approach using XPFR. RESULTS: The XPS removed more filling material in the BCS and AHS groups, compared with the AHW group (P < 0.05). After supplementary instrumentation XPFR, the proportion of the remaining filling material decreased significantly in all groups (P < 0.05). The XPFR instruments were more efficient in removing filling material in the BCS group than in the AHS or AHW group (P < 0.05). The combined use of XPS and XPFR instruments efficiently removed filling material in the BCS group, followed by the AHS and AHW groups (P < 0.05). CONCLUSIONS: Although the combined use of XPS and XPFR instruments helped remove the bulk of aged root filling material from mandibular molars, material removal from canals filled using warm vertical condensation in the critical apical area remains a concern. CLINICAL SIGNIFICANCE: Removal of the aged filling materials using XP-endo instruments from the apical area is challenging when instrumented root canals are filled using warm vertical condensation.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Liu H, Lai WWM, Hieawy A, et al. Efficacy of XP-endo instruments in removing 54 month-aged root canal filling material from mandibular molars. J Dent. 2021. PMID: 34182059. doi:10.1016/j.jdent.2021.103734

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。