文献速递牙体牙髓病

根管封闭剂根尖挤出后术后疼痛比较:硅酸钙基与树脂基

Comparison of Postobturation Pain Experience after Apical Extrusion of Calcium Silicate- and Resin-Based Root Canal Sealers.
PubMed 文献 · J Endod · 2021-05-29

本研究纳入330例无症状不可逆性牙髓炎磨牙行根管治疗的患者,随机分为AH Plus、BC Sealer和Bio-C Sealer三组(每组110例),比较封闭剂意外根尖挤出后的术后疼痛强度。挤出率各组约12%,三组间术后疼痛无显著差异(P > .05),疼痛均为低强度。

要点

  • 硅酸钙基与树脂基封闭剂根尖挤出后术后疼痛强度相似,均为低强度。
  • 挤出率各组约12%,三组间无显著差异。
  • AH Plus和Bio-C Sealer在12小时后疼痛显著下降,BC Sealer至1周仍无显著变化。

核心结论

  • 硅酸钙基根管封闭剂意外根尖挤出后的术后疼痛结果与树脂基封闭剂相似,均为低强度疼痛。

研究设计与样本

  • 随机对照试验,纳入330例因无症状不可逆性牙髓炎接受磨牙根管治疗的患者,随机分为AH Plus、BC Sealer和Bio-C Sealer三组(每组110例)。
  • 根管预备使用WaveOne Gold器械冠向下技术,冲洗使用2%氯己定凝胶和生理盐水,根管充填采用垂直加压技术。
  • 对发生封闭剂意外挤出的患者(每组13例)在术后6、12、24、48小时和1周使用0-10视觉描述量表评估术后疼痛。

主要发现

  • 封闭剂挤出率各组相似(约12%)。
  • 三种封闭剂评估的术后疼痛结果无显著差异(P > .05)。
  • 12小时间隔后,AH Plus(P = .04073)和Bio-C Sealer(P = .04327)显示疼痛显著降低,而BC Sealer即使在评估的最大周期1周也未显示疼痛强度差异(P > .05)。

临床怎么用

  • 对于无症状不可逆性牙髓炎磨牙根管治疗,硅酸钙基和树脂基封闭剂根尖挤出后术后疼痛均为低强度且相似,封闭剂选择可基于其他临床因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study compared the intensity of postobturation pain after unintentional apical extrusion of calcium silicate-based root canal sealers (EndoSequence BC Sealer [Brasseler USA, Savannah, GA] and Bio-C Sealer [Angelus, Londrina, PR, Brazil]) with a resin-based sealer (AH Plus; Dentsply Sirona, York, PA). METHODS: A total of 330 patients referred for root canal treatment on molar teeth with asymptomatic irreversible pulpitis were recruited. Root canals were prepared using WaveOne Gold instruments (Dentsply Sirona) in a crown-down technique and irrigated with 2% chlorhexidine gel and saline solution. Next, patients were randomly distributed into 3 groups according to the root canal sealer used (n = 110): AH Plus, BC Sealer, and Bio-C Sealer. Root canal filling was then accomplished with a vertical compaction technique. Patients presenting with an unintentional extrusion of sealers (n = 13/group) were assessed for postobturation pain experience using a visual descriptor scale ranging from 0-10 at 6-, 12-, 24-, and 48-hour and 1-week intervals after treatment. Mixed analysis of variance repeated measures were used to assess the results (α = 0.05). RESULTS: The extrusion rate was similar for all sealers (~12%). There was no significant difference in the postobturation pain results between the root canal sealers evaluated (P > .05). However, after the time interval of 12 hours, AH Plus (P = .04073) and Bio-C Sealer (P = .04327) demonstrated a significant reduction in pain, whereas BC Sealer did not show differences in pain intensity, even in the maximum period evaluated of 1 week (P > .05). CONCLUSIONS: The occurrence of unintentional apical extrusion of calcium silicate-based root canal sealers presents similar postoperative pain results compared with resin-based sealers with low-intensity pain.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Drumond JPSC, Maeda W, Nascimento WM, et al. Comparison of Postobturation Pain Experience after Apical Extrusion of Calcium Silicate- and Resin-Based Root Canal Sealers. J Endod. 2021. PMID: 34058249. doi:10.1016/j.joen.2021.05.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。