文献速递牙体牙髓病

下颌磨牙中近中根管预备尺寸与锥度对牙根抗折性的影响

The Effect of Root Canal Preparation Size and Taper of Middle Mesial Canals on Fracture Resistance of the Mandibular Molar Teeth: An In Vitro Study.
PubMed 文献 · J Endod · 2021-06-09

结果显示25.04组与对照组无显著差异且均显著高于25.06、30.04、30.06组。结论提示增大中近中根管根尖直径和锥度会降低下颌磨牙的抗折强度。

要点

  • 中近中根管预备至25.04时抗折强度与不预备对照组无显著差异。
  • 预备尺寸超过25.04(如25.06、30.04、30.06)时抗折强度显著下降。
  • 在临床可及范围内,中近中根管宜选用较小预备尺寸以保留抗折性。

核心结论

  • 在本研究局限内,增大中近中根管的根尖直径和锥度会降低下颌磨牙的抗折强度。
  • 在所测试的器械尺寸中,当选择大于25.04的预备尺寸时抗折强度显著下降。

研究设计与样本

  • 去冠及远中根分离后,近中根长度标准化为13 mm,随机分为5组(n=11)。
  • 近中颊根管与近中舌根管均用VDW.ROTATE旋转器械预备至30.06。
  • 中近中根管分别预备至25.04、25.06、30.04、30.06,对照组不预备。
  • 冲洗后单尖法充填,试样包埋后万能试验机垂直加载至根折,采用单因素方差分析和Duncan事后检验(P = .05)。

主要发现

  • 25.04组与对照组之间无显著差异。
  • 25.04组和对照组的抗折强度显著高于25.06、30.04和30.06组(P < .05)。

关键数值与推荐

  • 中近中根管预备至25.04时抗折强度与不预备对照组无显著差异。
  • 中近中根管预备至25.06、30.04、30.06时抗折强度显著低于25.04组和对照组(P < .05)。

临床怎么用

  • 对含中近中根管的下颌磨牙进行根管治疗时,可优先考虑不超过25.04的预备尺寸以保留抗折强度。
  • 避免不必要的扩大中近中根管根尖直径或增大锥度。

局限性

  • 本研究为体外研究,结论需结合临床实际谨慎应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The aim of the present study was to investigate the influence of root canal preparation size and taper of middle mesial (MM) canals on fracture resistance of mandibular molars. METHODS: Fifty-five mandibular molar teeth having an MM canal were selected based on the cone-beam computed tomographic analysis. After the decoronation and distal root separation procedure, the lengths of the mesial roots were standardized to 13 mm. The specimens were randomly distributed into 5 groups (n = 11). Mesiobuccal and mesiolingual canals were prepared up to size 30.06 using VDW.ROTATE rotary files (VDW, Munich, Germany). The MM canal was prepared up to size 25.04, 25.06, 30.04, and 30.06, respectively. No preparation was done in the MM canal in the control group. After the irrigation protocol, the canals were obturated with the single-cone technique. A thin layer of silicone-coated specimens was embedded in acrylic resin and subjected to a fracture strength test by a universal testing machine. A vertical force was applied to the roots until they fracture. Statistical analysis was performed with 1-way analysis of variance and post hoc Duncan tests (P = .05). RESULTS: There was no significant difference between group 25.04 and the control group, but the fracture strengths of these groups were found to be significantly higher than that of groups 25.06, 30.04, and 30.06 (P < .05). CONCLUSIONS: Within the limitations of this study, we concluded that increasing the apical diameter and taper in the MM canal reduces the fracture strength of mandibular molar teeth. Among the tested instrumentation sizes, fracture strength decreased significantly when greater than 25.04 instrumentation sizes were chosen.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Kılıç Y, Karataşlıoğlu E, Kaval ME, et al. The Effect of Root Canal Preparation Size and Taper of Middle Mesial Canals on Fracture Resistance of the Mandibular Molar Teeth: An In Vitro Study. J Endod. 2021. PMID: 34118255. doi:10.1016/j.joen.2021.06.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。