脉冲磁场对粪肠球菌的抑菌效应剂量学研究
该实验室研究测试了1、2、3、4 T脉冲磁场对粪肠球菌的抑菌效果,通过光密度监测、活死染色、膜电位、活性氧及显微成像评估。结果显示1、3、4 T显著抑制细菌生长,3 T和4 T在较长暴露后时间产生抑菌效应,4 T暴露2小时内出现膜电位改变和活性氧升高。结论为高场强脉冲磁场在实验室条件下对粪肠球菌具有抑菌作用。
要点
- 1、3、4 T脉冲磁场显著抑制粪肠球菌生长,2 T未见显著抑制。
- 3 T和4 T在较长暴露后时间表现出抑菌效应。
- 4 T暴露2小时内出现膜电位改变和活性氧升高。
核心结论
- 实验室条件下,较高场强(3 T和4 T)的脉冲磁场能够对粪肠球菌产生抑菌效应。
研究设计与样本
- 实验室研究,对细菌悬液施加1、2、3、4 T四种场强的脉冲磁场,每种场强重复三十次。
- 采用拾取线圈装置测量细菌悬液内诱导的电动势,并在处理后16小时40分钟内监测光密度以评估细菌生长。
主要发现
- 4 T磁场脉冲(脉宽16 ms)下诱导电动势峰值为0.25 V。
- 活死染色荧光显微镜定性结果显示较高场强(3 T/4 T)在较长暴露后时间诱导抑菌效应。
- 4 T脉冲磁场暴露2小时内出现膜电位改变,并伴有活性氧升高;ROS实验中4 T暴露样本差异显著(ANOVA:F(1,3)=20.2749,p=.05)。
- SEM和AFM观察显示明显的膜损伤,与上述结果一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To examine in a laboratory setting the efficacy of moderate to high strength magnetic fields, as a potential bacteriostatic stimulus, against Enterococcus faecalis, one of the causative agents for infection during root canal treatments. METHODOLOGY: Four different strengths (1, 2, 3 and 4 T) of the pulsed magnetic field (PMF) were applied in thirty repetitions to bacterial suspension. A pickup coil setup was used to measure the electromotive force induced inside the bacterial suspensions. The optical density (OD) was monitored over time (for 16 h 40 min) during the post-treatment period to assess bacterial growth. Along with the change in OD values, live/dead assay, membrane depolarization study, atomic force microscopy (AFM), scanning electron microscopy (SEM) and reactive oxygen species (ROS) assay on selected samples were studied to evaluate the effect of PMFs. All results were analysed using one-way ANOVA followed by post hoc Tukey test and considered significant at p < .05. Regression analysis (at a confidence of 95%, α = 0.05) was performed on the bacterial growth and membrane depolarization studies to determine progressive changes of the outcomes. RESULTS: The peak value of the induced electromotive force was recorded as 0.25 V, for the 4 T magnetic field pulse with a pulse width of 16 ms. There was a significant arrest of bacterial cell growth after an exposure to PMFs of 1 T, 3 T and 4 T (ANOVA score: F (4, 495) =395.180 at p = .05). The image-based qualitative results of the live/dead assay using fluorescence microscopy techniques indicated that an exposure to higher PMFs (3 T/ 4 T) induced a bacteriostatic effect in a longer post-exposure timescale. Evidence of altered membrane potential within the 2 h of exposure to 4 T PMF was supported by the incidence of elevated ROS. For the ROS assay, a significant difference occurred for 4 T exposed samples (ANOVA score: calculated F (1, 3) =20.2749 at p = .05). SEM and AFM observations corroborated with the outcomes, by portraying significant membrane damage. CONCLUSION: In a laboratory setting, PMFs with higher magnitudes (3 T and 4 T) were capable of inducing bacteriostatic effects on E. faecalis.
引用
- Naskar S, Chandan, Baskaran D, et al. Dosimetry of pulsed magnetic field towards attaining bacteriostatic effect on Enterococcus faecalis: Implications for endodontic therapy. Int Endod J. 2021. PMID: 34046919. doi:10.1111/iej.13580