不同工作长度下旋转、往复与自适应镍钛器械根管预备前后牙本质微裂纹形成的微CT比较评价
本研究用微CT比较旋转、往复和自适应镍钛器械在不同工作长度下预备下颌磨牙近中根后牙本质微裂纹的形成。ProTaper Universal在所有工作长度下均显著增加微裂纹(P ≤ .05),其余器械无显著增加(P > .05);不同工作长度对微裂纹形成无显著影响。
要点
- ProTaper Universal在所有工作长度下均显著增加预备后牙本质微裂纹。
- ProTaper Gold、Twisted File Adaptive和Reciproc Blue未显著增加微裂纹。
- 不同工作长度(短1mm、平齐、超1mm)对微裂纹形成无显著影响。
核心结论
- 旋转器械较往复和自适应器械诱导更多牙本质微裂纹。
- 不同工作长度对牙本质微裂纹形成无显著影响。
研究设计与样本
- 随机分为4组(n=45)按镍钛器械系统:ProTaper Universal、ProTaper Gold、Twisted File Adaptive、Reciproc Blue。
- 每组再分3亚组(n=15)按工作长度:短于主根尖孔1mm、平齐、超出1mm。
- 预备前后行微CT扫描,筛查横断面图像以检测新微裂纹。
主要发现
- ProTaper Universal在所有工作长度下均显著增加预备后微裂纹数(P ≤ .05)。
- ProTaper Gold、Twisted File Adaptive和Reciproc Blue组预备后微裂纹无显著增加(P > .05)。
临床怎么用
- 选择镍钛器械时可考虑往复或自适应系统以降低牙本质微裂纹风险。
- 工作长度设置在短1mm至超1mm范围内对微裂纹形成无显著影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study aimed to compare root dentinal microcrack formation after root canal shaping using rotary, reciprocating, and adaptive instruments at different working lengths using micro-computed tomographic imaging. METHODS: One hundred eighty extracted mature mandibular molar mesial roots with 2 separate canals were selected. The mesial roots were resected at the cementoenamel junction and randomly divided into 4 groups (n = 45) based on the nickel-titanium file system used: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Gold (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and Reciproc Blue (VDW, Munich, Germany). Each of the 4 groups were then subdivided into 3 groups (n = 15) depending on the working length used for root canal preparation (ie, instrumentation 1 mm short, flush, and 1 mm beyond the major apical foramen). The roots were imaged with micro-computed tomographic scanning before and after root canal preparation. The cross-sectional images generated were screened to detect the presence of new microcracks. RESULTS: The ProTaper Universal system significantly increased the number of postinstrumentation microcracks at all working lengths (P ≤ .05). No significant increase (P > .05) in postinstrumentation microcracks was observed in the ProTaper Gold, Twisted File Adaptive, or Reciproc Blue groups. CONCLUSIONS: Rotary instrumentation induced a higher number of dentinal microcracks compared with reciprocating and adaptive instruments. Instrumentation at different working lengths did not significantly influence the formation of dentinal microcracks.
引用
- Aggarwal A, Nawal RR, Yadav S, et al. Comparative Evaluation of Dentinal Microcrack Formation before and after Root Canal Preparation Using Rotary, Reciprocating, and Adaptive Instruments at Different Working Lengths-A Micro-computed Tomographic Study. J Endod. 2021. PMID: 34023360. doi:10.1016/j.joen.2021.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。