文献速递牙体牙髓病

新型基于体积的锥形束CT根尖周指数

A Novel Volume-based Cone-beam Computed Tomographic Periapical Index.
PubMed 文献 · J Endod · 2021-05-10

本研究评估了锥形束CT根尖周指数(CBCTPAI)评分的根尖周病变体积变异,并开发了基于体积的新指数。通过三维医学影像软件对273个根尖周病变进行半自动分割,测量最大直径和体积。结果显示CBCTPAI 3、4、5分的病变体积变异大,新指数CBCTPAVI分类准确率达98.169%,敏感性和特异性均≥0.90。

要点

  • CBCTPAI 3、4、5分病变体积变异大,难以预测体积和治疗结果。
  • 新指数CBCTPAVI基于三维真实大小分类,分类准确率98.169%。
  • CBCTPAVI敏感性和特异性高,有助于评估愈合和预测治疗结果。

核心结论

  • CBCTPAVI可基于病变真实三维大小分类,准确评估愈合和预测治疗结果。

研究设计与样本

  • 研究纳入有根尖周透射影或牙髓治疗史的牙齿,共分析273个根尖周病变。
  • 使用Mimics Research软件半自动分割测量病变体积和最大直径,并确定CBCTPAI评分。

主要发现

  • CBCTPAI 3、4、5分的病变体积存在显著变异,表现为方差和范围大。
  • 新指数CBCTPAVI的敏感性、特异性、精确度和曲线下面积均≥0.90,仅CBCTPAVI 1的敏感性为0.875。
  • CBCTPAVI总体准确分类率为98.169%,均方根误差低至0.07。

关键数值与推荐

  • CBCTPAVI 1的敏感性为0.875,其余指标均≥0.90。
  • 总体准确分类率为98.169%,均方根误差为0.07。

临床怎么用

  • 临床可使用CBCTPAVI基于病变三维体积进行分类,更准确评估愈合和预测治疗结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study was to evaluate the variations in the volume of periapical lesions scored using a cone-beam computed tomographic periapical index (CBCTPAI) and to develop a new volume-based periapical index. METHODS: Cone-beam computed tomographic images were obtained from InteleViewer (Intelerad Medical Systems Incorporated, Montreal, Canada). Teeth with a periapical radiolucency or with a history of endodontic treatment were included in this study. Using 3-dimensional medical imaging processing software (Mimics Research; Materialise NV, Leuven, Belgium), the maximum diameter of 273 periapical lesions and their corresponding CBCTPAI score was determined. The software was then used to determine the volume of the lesions using a semiautomatic segmentation technique. RESULTS: There was a substantial variation in the volume for CBCTPAI scores 3, 4, and 5, which was demonstrated by the variance and range, thus making it difficult to use the current CBCTPAI as a method to predict volume and treatment outcomes. A new index, the cone-beam computed tomographic periapical volume index (CBCTPAVI), was developed using partition classification analysis. The results for the new index demonstrated high levels of sensitivity, specificity, precision, and area under the curve, all at 0.90 or more, except 1 sensitivity for CBCTPAVI 1 at 0.875. Overall, the accurate classification rate was 98.169%, and the root mean square error rate was low at 0.07. CONCLUSIONS: The proposed CBCTPAVI will allow clinicians to classify lesions based on their true 3-dimensional size, accurately assess healing of lesions, and predict treatment outcomes.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Boubaris M, Chan KL, Zhao W, et al. A Novel Volume-based Cone-beam Computed Tomographic Periapical Index. J Endod. 2021. PMID: 33984376. doi:10.1016/j.joen.2021.04.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。