根管封闭剂与牙胶粘接强度评估的新方法学提案
本研究采用新型微剪切粘接强度测试方法,比较环氧树脂类封闭剂AH Plus与两种硅酸钙类封闭剂(EndoSequence BC Sealer和EndoSeal MTA)对牙胶圆盘的粘接强度。结果显示AH Plus的中位剪切粘接强度显著高于两种硅酸钙类封闭剂,所提方法具有创新性和可重复性。
要点
- AH Plus对牙胶的中位剪切粘接强度为1.43 MPa,显著高于两种硅酸钙类封闭剂。
- EndoSequence BC Sealer中位值最低(0.45 MPa),EndoSeal MTA为0.53 MPa。
- 新型微剪切测试装置未出现提前失败,方法可重复。
核心结论
- 硅酸钙类封闭剂对牙胶的粘接强度弱于环氧树脂类AH Plus封闭剂。
- 所提出的方法是一种创新且可重复的根管封闭剂与牙胶粘接强度测试方法。
研究设计与样本
- 体外研究,使用60个直径10 mm、厚2 mm的牙胶圆盘,每种封闭剂制备10个样本进行微剪切粘接强度测试。
- 采用Kruskal-Wallis检验及事后比较,α误差设为5%。
主要发现
- 所有封闭剂对牙胶均有不同程度粘接,组间差异显著(Kruskal-Wallis,p = .019)。
- AH Plus中位剪切粘接强度为1.43 MPa(1.40-1.83),显著高于EndoSeal MTA的0.53 MPa(0.46-0.73)(p = .021)。
- AH Plus显著高于EndoSequence BC Sealer的0.45 MPa(0.34-0.46)(p = .023)。
- EndoSequence BC Sealer中位值最低(p < .05)。
- 总体未发生提前失败。
临床怎么用
- 在选择根管封闭剂时,若需增强与牙胶的粘接,AH Plus可能优于所测硅酸钙类封闭剂。
- 新型微剪切测试装置可作为评估封闭剂-牙胶粘接强度的可重复方法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To compare the bond strength of an epoxy resin-based sealer and two calcium silicate-based sealers (CSS) to gutta-percha discs using a new method. METHODOLOGY: Round discs of gutta-percha (n = 60), measuring 10 mm in diameter and 2 mm in thickness, were placed on a glass plate and a drop of each sealer (AH Plus, EndoSequence BC Sealer and EndoSeal MTA) was placed on their surface. Another identical disc was placed onto the first one and a standardized weight (0.0981 N) applied over them using a specially developed apparatus. Ten samples prepared for each sealer were submitted to a microshear bond strength test accomplished by a specially designed set-up coupled to a universal testing machine. The Kruskal-Wallis test followed by a post hoc procedure was used to compare groups considering the preliminary analysis of the raw data had indicated the nonadherence to a Gaussian distribution (Shapiro-Wilk, p < .05). Alpha error was set at 5%. RESULTS: Overall, no premature failure occurred. All sealers had some degree of adhesiveness to gutta-percha discs but with a significant difference amongst them (Kruskal-Wallis, p = .019). The epoxy resin-based sealer (AH Plus) had significantly higher median shear bond strength values (1.43 MPa; 1.40-1.83) compared to EndoSeal MTA (0.53 MPa; 0.46-0.73) (p = .021) and EndoSequence BC Sealer (0.45 MPa; 0.34-0.46) (p = .023), whilst the lowest median value was observed with EndoSequence BC Sealer (0.45 MPa; 0.34-0.46) (p < .05). CONCLUSIONS: CSS sealers had weaker bonding to gutta-percha when compared to the epoxy resin-based AH Plus sealer. The proposed methodology is an innovative and reproducible method for testing the bond strength of root canal sealers to gutta-percha.
引用
- De-Deus G, Oliveira DS, Cavalcante DM, et al. Methodological proposal for evaluation of adhesion of root canal sealers to gutta-percha. Int Endod J. 2021. PMID: 33977555. doi:10.1111/iej.13549
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。