文献速递牙体牙髓病

新型三维打印模型评估超声活化冲洗清除生物膜效果

A novel three-dimensionally printed model to assess biofilm removal by ultrasonically activated irrigation.
PubMed 文献 · Int Endod J · 2021-07-08

本研究应用三维打印弯曲根管牙齿模型,在根尖三分之一处嵌入人牙本质样本,培养多物种生物膜21天后比较三种超声活化冲洗系统与注射器冲洗清除生物膜的效果。结果显示,所有超声活化NaOCl组菌落形成单位均显著低于注射器冲洗和对照组(p<.05),其中蓝色热处理镍钛锉的抗菌和生物膜清除效果最佳。

要点

  • 超声活化NaOCl冲洗比注射器冲洗更能有效减少根管内细菌。
  • 蓝色热处理镍钛超声锉在本模型中抗菌及清除生物膜效果最佳。
  • 不同超声锉的抗菌膜效果存在差异,临床选择需考虑锉的类型。

核心结论

  • 不同超声锉的抗菌膜效果存在差异,蓝色热处理镍钛超声锉在本标准化根管模型中抗菌和清除牙本质生物膜效果最佳。

研究设计与样本

  • 采用三维打印弯曲根管牙齿模型,根尖三分之一处设标准化槽以精确嵌入人牙本质样本。
  • 在根管内培养含粪肠球菌、轻型链球菌和直肠弯曲杆菌的多物种生物膜21天。
  • 根管随机分配至1%次氯酸钠注射器冲洗组、不锈钢锉超声活化组、常规镍钛锉超声活化组或蓝色热处理镍钛锉超声活化组,蒸馏水冲洗感染根管为对照。
  • 细菌减少通过菌落形成单位计数评估(n=20),生物膜通过共聚焦激光扫描显微镜(n=7)和场发射扫描电子显微镜分析。

主要发现

  • 所有超声活化NaOCl组的菌落形成单位值均显著低于注射器冲洗组和对照组(p<.05)。
  • 不锈钢锉和蓝色热处理镍钛锉超声活化组的生物膜体积显著低于其他组(p<.05)。
  • 总体而言,蓝色热处理锉超声活化冲洗的抗菌和生物膜清除效果最高。

关键数值与推荐

  • 菌落形成单位计数比较采用独立样本t检验(Welch t检验),p<.05认为有统计学意义。
  • 共聚焦激光扫描显微镜数据采用单因素方差分析(ANOVA)及Scheffé事后检验。

临床怎么用

  • 对于需去除根管内多物种生物膜的病例,可优先考虑超声活化NaOCl冲洗而非单纯注射器冲洗。
  • 选择超声锉时,蓝色热处理镍钛锉在本模型中显示最优抗菌膜效果,可作为临床参考。

局限性

  • 本研究为体外三维打印模型研究,结果需临床研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To apply an innovative three-dimensionally printed tooth model to investigate the efficacy of three ultrasonically activated irrigation (UAI) systems in removing multispecies biofilms from dentine samples. METHODOLOGY: Three-dimensionally printed teeth with a curved root canal were fabricated with a standardized slot in the apical third of the root to achieve precision fit of human root dentine specimens. Multispecies biofilms including Enterococcus faecalis, Streptococcus mitis and Campylobacter rectus were developed in the root canal for 21 days. The canals were allocated to be irrigated with 1% sodium hypochlorite (NaOCl) using a syringe and needle or ultrasonically activated NaOCl with a stainless-steel file (Irrisafe), a conventional nickel-titanium (Ni-Ti) file (CK) or a blue heat-treated Ni-Ti file (Endosonic Blue). Infected root canals irrigated with distilled water served as controls. Bacterial reduction was determined by colony-forming unit (CFU) counting (n = 20), whilst biofilms were analysed using confocal laser scanning microscopy (n = 7) and field emission scanning electron microscopy. For CFU counting, the independent two-sample t-test (Welch's t-test) was examined to compare overall bacterial reduction amongst groups. For CLSM analysis, the data were analysed using one-way analysis of variance (ANOVA), followed by the Scheffé post hoc test. The p-values <.05 were considered to indicate statistical significance. RESULTS: All groups in which NaOCl was ultrasonically activated had significantly lower CFU values than the syringe-and-needle irrigation and control groups (p < .05). Ultrasonic activation with the stainless-steel file and blue heat-treated Ni-Ti file significantly reduced the biofilm volume compared with other groups (p < .05). Overall, UAI with the blue heat-treated file resulted in the highest antibacterial and biofilm removal efficacy. CONCLUSIONS: UAI with different inserts had differential antibiofilm effects. The blue heat-treated Ni-Ti ultrasonic insert resulted in the greatest antibacterial and biofilm removal from dentine in this standardized root canal model.