文献速递口腔修复与种植

全牙弓螺丝固位与套筒冠固位种植固定修复的边缘骨吸收及风险指标:回顾性病例对照研究

Marginal bone loss and the risk indicators of fixed screw-retained implant-supported prostheses and fixed telescopic-retained implant-supported prostheses in full arch: A retrospective case-control study.
PubMed 文献 · Clin Oral Implants Res · 2021-04-07

本研究比较全牙弓螺丝固位(FSI-FDP)与带专业检索系统的套筒冠固位(FTI-FDP)种植固定修复体在7-13年后的边缘骨吸收(MBL)、MBL≥1 mm风险指标及种植体周围炎率。两组平均MBL相当,但FTI-FDP组MBL≥1 mm风险更低,种植体周围炎率无显著差异。

要点

  • FSI-FDP与FTI-FDP种植体平均MBL相当(0.60±0.51 vs 0.41±1.03 mm)。
  • FTI-FDP组MBL≥1 mm的种植体比例(6.9%)低于FSI-FDP组(25%)。
  • 上部结构-基台连接和种植体-基台连接与MBL≥1 mm相关。

核心结论

  • FSI-FDP与FTI-FDP种植体平均MBL相当,但FTI-FDP发生MBL≥1 mm的风险低于FSI-FDP。
  • 种植体-基台连接是MBL≥1 mm的风险指标。
  • 两组种植体周围炎率表现相似。

研究设计与样本

  • FSI-FDP组26例患者(32件修复体、202枚种植体),FTI-FDP组39例患者(54件修复体、390枚种植体)。
  • 评估MBL、MBL≥1 mm的风险指标及13年时种植体周围炎率。

主要发现

  • FSI-FDP与FTI-FDP种植体平均MBL分别为0.60±0.51 mm和0.41±1.03 mm。
  • MBL≥1 mm在FSI-FDP种植体中占25%,在FTI-FDP种植体中占6.9%。
  • 上部结构-基台连接(螺丝固位FSI-FDP > 套筒冠固位FTI-FDP)和种植体-基台连接(外对接、内对接 > 莫氏锥度连接)与MBL≥1 mm相关。
  • 种植体水平种植体周围炎率:FSI-FDP组3.99%(95%CI=3.93-20.5),FTI-FDP组3.85%(95%CI=3.85-34.3),无显著性差异。

关键数值与推荐

  • MBL≥1 mm的风险指标包括上部结构-基台连接类型(螺丝固位风险高于套筒冠固位)和种植体-基台连接类型(外对接、内对接风险高于莫氏锥度连接)。

临床怎么用

  • 全牙弓种植固定修复选择固位方式时,可考虑套筒冠固位以降低MBL≥1 mm风险。
  • 关注种植体-基台连接类型,莫氏锥度连接可能较外对接或内对接更有利于减少MBL≥1 mm。
  • 两组种植体周围炎率相似,长期维护中均需监测种植体周围炎。

局限性

  • 回顾性病例对照设计,可能存在选择偏倚和信息偏倚。
  • 样本来自单一研究,结论需更大样本前瞻性研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study compared full-arch screw-retained implant-supported fixed dental prostheses (FSI-FDPs) and full-arch telescopic-retained implant-supported fixed dental prostheses with a professional retrieval system (FTI-FDPs) on marginal bone loss (MBL), the risk indicators and peri-implantitis rate after 7-13 years. MATERIAL AND METHODS: Sixty five edentulous patients were treated with 86 prostheses and 592 implants. The FSI-FDP group comprised 26 patients (32 prostheses, 202 implants), and the FTI-FDP group comprised 39 patients (54 prostheses, 390 implants). MBL and the risk indicators of MBL ≥1 mm were assessed. Peri-implantitis rates at 13 years were also calculated. RESULTS: Full-arch screw-retained implant-supported fixed dental prostheses and FTI-FDP implants exhibited comparable mean MBLs of 0.60 ± 0.51 and 0.41 ± 1.03 mm, respectively. MBL ≥1 mm was noted for 25% of FSI-FDP implants and 6.9% of FTI-FDP implants. Superstructure-abutment connection (screw retention:FSI-FDPs >telescopic retention:FTI-FDPs) and implant-abutment connection (External butt joint, Internal butt joint >Morse taper joint) were associated with MBL ≥1 mm. Peri-implantitis rates at the implant level were 3.99% (95%CI = 3.93-20.5) in FSI-FDP group and 3.85% (95%CI = 3.85-34.3) in FTI-FDP group with no significance. CONCLUSIONS: It was concluded that FSI-FDP and FTI-FDP implants exhibited comparable MBL; however, the risk of MBL ≥1 mm in FTI-FDPs was lower than in FSI-FDPs. Besides, implant-abutment connection was the risk indicator of MBL ≥1 mm. In peri-implantitis rate, FSI-FDPs and FTI-FDPs behave similarly.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Oda Y, Mori G, Honma S, et al. Marginal bone loss and the risk indicators of fixed screw-retained implant-supported prostheses and fixed telescopic-retained implant-supported prostheses in full arch: A retrospective case-control study. Clin Oral Implants Res. 2021. PMID: 33754378. doi:10.1111/clr.13750

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。