这项原理验证研究将100颗离体人牙(前牙和前磨牙)固定于上下颌模型,用MRI扫描并结合口内扫描规划开髓洞形,通过CAD/CAM制作导板完成开髓。结论认为MRI适用于引导牙髓开髓。

要点

  • 开髓角度平均偏差1.82°,车针偏差在亚毫米级。
  • 下颌牙颊舌向精度优于上颌,前牙近远中向精度优于前磨牙。

核心结论

  • 这项体外研究证明MRI适用于引导牙髓开髓洞形的预备。

研究设计与样本

  • 原理验证性体外研究,使用100颗离体人牙(前牙和前磨牙)固定于5个下颌和5个上颌模型。
  • 模型装配含薄层水凝胶的导板用于间接成像,经MRI扫描后与口内扫描配准规划开髓,CAD/CAM制作导板完成开髓。
  • 通过CBCT扫描与虚拟规划数据匹配,评估开髓在近远中向、颊舌向及角度上的偏差。

主要发现

  • 平均角度偏差为1.82°。
  • 车针基部平均偏差范围为0.21-0.31 mm,尖端为0.28-0.44 mm。
  • 颊舌向预备在下颌牙显著比上颌牙精确,近远中向精度在前牙优于前磨牙。

关键数值与推荐

  • 平均角度偏差1.82°,车针基部偏差0.21-0.31 mm,尖端偏差0.28-0.44 mm。

临床怎么用

  • 为MRI作为引导牙髓开髓的影像手段提供了初步体外证据,提示可用于规划开髓洞形。
  • 亚毫米级偏差和较小角度偏差表明MRI引导开髓在体外模型中具有可行性。

局限性

  • 本研究为体外原理验证,使用离体牙和模型,非临床在体条件。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This proof-of-principle study aimed to demonstrate that magnetic resonance imaging (MRI) is sufficiently accurate for the detection of root canals using guided endodontics. METHODS: One hundred extracted human teeth (anterior and premolar) were mounted onto 5 mandibular and 5 maxillary models, fitted with splints designed to accommodate a thin layer of aqueous gel for indirect imaging, and scanned by MRI. After MRI and intraoral scans were aligned using planning software, access cavities were planned virtually, and templates were manufactured with computer-aided design/computer-aided manufacturing, the access cavities were prepared. Cone-beam computed tomographic scans were performed and matched with the virtual preoperative planning data to determine the accuracy of access cavity preparation in terms of deviation between planned and prepared cavities in the mesiodistal and buccolingual dimensions and angle. Descriptive statistical analysis was performed, and the mean values were compared using the t test. RESULTS: Ninety-one of 100 root canals were successfully scouted after MRI-guided access cavity preparation. The mean angle deviation was 1.82°. The mean deviation ranged from 0.21-0.31 mm at the base of the bur and from 0.28-0.44 mm at the tip of the bur. Preparation in the buccolingual dimension was significantly more precise in mandibular compared with maxillary teeth, and accuracy in the mesiodistal dimension was more precise in anterior teeth compared with premolars. CONCLUSIONS: This in vitro study demonstrated the suitability of MRI for guided endodontic access cavity preparation.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Leontiev W, Bieri O, Madörin P, et al. Suitability of Magnetic Resonance Imaging for Guided Endodontics: Proof of Principle. J Endod. 2021. PMID: 33774047. doi:10.1016/j.joen.2021.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。