Nd:YAP激光消融根管内分离锉的效率与根面温度升高的体外研究
本体外研究评估了Nd:YAP激光消融根管内分离锉的效率及根面温度升高。每5脉冲消融锉长度平均0.113-0.158 mm,不同锉间无统计学差异;根面温度升高均低于10°C,2脉冲组低于5脉冲组,合金类型和直径不影响温升。结论认为少于5脉冲时根面温升对牙周组织安全。
要点
- Nd:YAP激光可消融不锈钢或镍钛分离锉,每5脉冲消融长度0.113-0.158 mm。
- 根面温度升高均低于10°C,2脉冲模式温升低于5脉冲模式。
- 锉的直径或合金类型对根面温度升高无影响。
核心结论
- 分离的不锈钢或镍钛锉可通过Nd:YAP激光消融,当脉冲数少于5时根面温度升高对周围牙周组织安全。
研究设计与样本
- 体外研究,第一部分使用#10、#15 C锉和ProTaper Next X1、X2锉,在8.5×下用Nd:YAP激光从锉尖开始消融,每5脉冲记录锉长度。
- 第二部分将#15 C锉和ProTaper Next X2各3根分离于6颗下颌第二磨牙单根管远中根内,用2脉冲和5脉冲模式消融,红外相机记录根面温度升高,另3颗未处理远中根为阴性对照。
- 扫描电镜评估锉和根管壁表面变化。
主要发现
- 每5脉冲消融后锉平均长度为0.113-0.158 mm,不同锉之间无统计学差异。
- 阴性对照组根面温度升高(2脉冲和5脉冲组分别为1.86°±0.11°C和5.81°±0.35°C)显著低于含分离锉的根(2脉冲C锉和ProTaper Next X2分别为3.74°±0.20°C和4.02°±0.11°C;5脉冲C锉和ProTaper Next X2分别为8.47°±0.19°C和9.04°±0.20°C)。
- 所有组根面温度升高均低于10°C,2脉冲组温度升高低于5脉冲组,锉直径或合金类型对温度升高无影响。
关键数值与推荐
- 每5脉冲消融锉长度平均0.113-0.158 mm。
- 根面温度升高:阴性对照2脉冲组1.86°±0.11°C、5脉冲组5.81°±0.35°C;含分离锉2脉冲组3.74°±0.20°C(C锉)和4.02°±0.11°C(ProTaper Next X2);5脉冲组8.47°±0.19°C(C锉)和9.04°±0.20°C(ProTaper Next X2)。
- 所有组温度升高低于10°C。
临床怎么用
- Nd:YAP激光可用于消融根管内分离的金属锉,但需控制脉冲数少于5以保持根面温升安全。
- 临床操作中可优先考虑2脉冲模式以减少根面温度升高。
局限性
- 本研究为体外实验,结果需临床进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Retrieving a separated file in the root canal system requires a skilled clinician. A metal file can be removed by ablation via the neodymium:yttrium-aluminum-perovskite (Nd:YAP) laser; however, the efficiency and potential hazards of the ablation procedure are still unclear. The aim of this study was 2-fold: to investigate the efficiency of file ablation using the Nd:YAP laser and to evaluate the rise in temperature of the root surface in vitro. METHODS: In part 1 of this study, #10 and #15 C-files (VDW GmbH, Munich, Germany) and ProTaper Next X1 and X2 files (Dentsply Maillefer, Ballaigues, Switzerland) were selected. Under 8.5×, the Nd:YAP laser was used to ablate the files starting at the tip of the file. The length of the file was recorded after each 5-pulse ablation. In part 2 of this study, 3 files each of the #15 C-file and the ProTaper Next X2 were separated in 6 distal roots of mandibular second molars with single canals. Two-pulse and 5-pulse modes were used to ablate the separated files, and the rise in root surface temperature was recorded with an infrared camera. Another 3 unaltered distal roots served as the negative control. For scanning electron microscopic evaluation, the teeth were split with bone scissors and observed under a scanning electron microscope to evaluate the surface change of the file and the root canal wall. RESULTS: The average length of the ablated files after each 5-pulse interval was 0.113-0.158 mm with no statistical difference between the different files.The temperature rise of the negative control group (mean ± standard deviation = 1.86° ± 0.11°C and 5.81° ± 0.35°C for the 2- and 5-pulse group) was significantly lower than the roots with separated files (mean ± standard deviation = 3.74° ± 0.20°C and 4.02° ± 0.11°C for 2-pulse C-file and ProTaper Next X2; 8.47° ± 0.19°C and 9.04° ± 0.20°C for 5-pulse C-file and ProTaper Next X2). The temperature rise of all groups was lower than 10°C. The 2-pulse group showed a lower temperature rise than the 5-pulse group. The diameter or the type of alloy had no effect on the temperature rise. CONCLUSIONS: Separated files (stainless steel or nickel-titanium alloy) can be ablated by the Nd:YAP laser. When the number of pulses is less than 5, the temperature rise of the root surface is considered safe to the surrounding periodontium.