文献速递口腔修复与种植口腔颌面外科

静态导航种植备洞中骨内产热的多因素体外研究

Intra-osseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study.
PubMed 文献 · Clin Oral Implants Res · 2021-03-21

该体外研究在16个聚氨酯泡沫块上完成960次2 mm先锋钻备洞,比较开窗与闭窗静态导板、骨密度、备洞深度及冲洗液温度对骨内温度的影响。结果显示闭窗导板温度约高1°C,硬骨产热最高,冲洗液冷却至5°C可大幅降低产热。

要点

  • 闭窗静态导板备洞温度较开窗导板约高1°C。
  • 高密度骨备洞产热最高,软骨质产热较低。
  • 冲洗液冷却至5°C可显著降低备洞产热。

核心结论

  • 高密度骨备洞产热最大,闭窗静态导板比开窗导板骨内终温约高1°C。
  • 冲洗液冷却至5°C可大幅降低备洞部位产热。

研究设计与样本

  • 体外研究,在16个固体硬质聚氨酯泡沫块上用2 mm先锋钻完成960次备洞。
  • 按导板类型(开窗或闭窗)和骨密度(硬骨D1或软骨质D4)分为四组。
  • 实验条件组合包括备洞深度6或13 mm及冲洗液温度5°C或21°C。

主要发现

  • 最高平均温度出现在闭窗导板硬骨组,为28.29 ± 4.02°C。
  • 软骨质组中闭窗导板平均最高温度为23.38 ± 1.92°C,开窗导板为21.97 ± 1.22°C(p < .001)。
  • 备洞深度和冲洗液温度也显著影响骨温度(p < .001),尤其在硬骨中。

关键数值与推荐

  • 闭窗静态导板比开窗导板骨内终温约高1°C。
  • 冲洗液冷却至5°C可大幅降低备洞部位产热。

临床怎么用

  • 高密度骨备洞时应关注产热,可考虑使用开窗导板或冷却冲洗液至5°C。
  • 闭窗静态导板备洞时需注意额外约1°C的温度升高。

局限性

  • 研究为体外聚氨酯泡沫块模型,非活体骨组织。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the intra-osseous temperature reached during bone drilling for dental implant placement using open versus closed static surgical guides and evaluate the influence of bone density, osteotomy drilling depth, and irrigation fluid temperature. MATERIAL AND METHODS: 960 osteotomies were performed with 2 mm pilot drills in 16 solid rigid polyurethane foam blocks. Two main variables were considered: the guide type (open or closed guide) and bone density (hard (D1) or soft (D4). The blocks were divided into four groups according to the type of surgical template and bone density as follows: group one: closed guide and hard bone; group two: open guide and hard bone; group three: closed guide and soft bone; and group four: open guide and soft bone. A combination of different experimental conditions was used, including different bone osteotomy depths (6 or 13 mm) and irrigation fluid temperatures (5°C or 21°C). RESULTS: The highest mean temperature was found in group one (28.29 ± 4.02°C). In the soft bone groups (three and four), the mean maximum temperature decreased compared to groups one and two (dense bone) and was always higher with closed guides (23.38 ± 1.92°C) compared to open guides (21.97 ± 1.22°C) (p < .001). The osteotomy depth and irrigation fluid temperature also significantly influenced the bone temperature (p < .001), especially in hard bone. CONCLUSIONS: The greatest heat generation was observed in high-density bone. The final intra-bone temperature was about 1°C higher with a closed static surgical guide than with an open guide. The heat generation in osteotomy sites was substantially reduced by cooling the irrigation fluid to 5°C.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Gargallo-Albiol J, Salomó-Coll O, Lozano-Carrascal N, et al. Intra-osseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study. Clin Oral Implants Res. 2021. PMID: 33629419. doi:10.1111/clr.13728

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。