晚期牙周炎患者系列3D模型重叠参考区域的评估
本研究旨在确定晚期牙周炎患者系列3D牙模型重叠的最佳参考区域。结果显示,区域A(所有稳定牙)和区域B(所有牙)提供最高精度,在稳定牙评估区域的平均绝对距离分别为71±29 μm和73±21 μm。
要点
- 区域A和B重叠精度最高,稳定牙评估区域达71±29 μm和73±21 μm。
- 区域C(第三腭皱襞)和D(全模型)精度较低,分别为127±52 μm和113±53 μm。
- 除区域C外,所有参考区域的ICC值均>0.990,重复性高。
核心结论
- 对于晚期牙周炎患者口内扫描获得的系列3D牙模型,参考区域A(所有稳定牙)和B(所有牙)提供最高的重叠精度。
主要发现
- 在稳定牙评估区域,区域A、B、C、D的重叠精度分别为71±29 μm、73±21 μm、127±52 μm和113±53 μm。
- 所有参考区域的ICC值均>0.990,但区域C在牙评估区域的ICC为0.821(操作者内)和0.767(操作者间)。
临床怎么用
- 在晚期牙周炎患者系列3D模型体积软组织评估中,优先选择所有稳定牙或所有牙作为重叠参考区域以确保高精度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: This study aimed to determine the optimal reference area for superimposition of serial 3D dental models of patients with advanced periodontitis. MATERIALS AND METHODS: Ten pre- and post-periodontal treatment 3D models (median time lapse: 13.1 months) of patients with advanced periodontitis were acquired by intraoral scanning. Superimposition was performed with the iterative closest point algorithm using four reference areas: (A) all stable teeth, (B) all teeth, (C) third palatal rugae and (D) the whole model. The superimposition accuracy was evaluated at two stable evaluation regions using the mean absolute distance and evaluated with two-way ANOVA and post-hoc multivariate model. The intra- and inter-operator reproducibility was calculated by intraclass correlation coefficient (ICC). RESULTS: Superimposition accuracy evaluated at stable tooth evaluation region were 71 ± 29 μm, 73 ± 21 μm, 127 ± 52 μm and 113 ± 53 μm for areas A, B, C and D, respectively. All reference areas showed similarly high ICC values >0.990, except for reference area C showing ICC of 0.821 (intra-operator) and 0.767 (inter-operator) for tooth evaluation area. CONCLUSIONS: Area A and B provide the highest accuracy for superimposition of serial 3D dental models acquired by intraoral scanning of patients with advanced periodontitis.
引用
- Kuralt M, Fidler A. Assessment of reference areas for superimposition of serial 3D models of patients with advanced periodontitis for volumetric soft tissue evaluation. J Clin Periodontol. 2021. PMID: 33576011. doi:10.1111/jcpe.13445
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。