文献速递牙体牙髓病

转速对连续旋转与OTR运动中扭矩/力及成形能力的影响

Influence of rotational speed on torque/force generation and shaping ability during root canal instrumentation of extracted teeth with continuous rotation and optimum torque reverse motion.
PubMed 文献 · Int Endod J · 2021-07-12

研究使用JIZAI镍钛器械在离体下颌磨牙近中根管中比较300与500 rpm转速下连续旋转和OTR运动的扭矩/力及成形能力。结果显示500 rpm组最大上抬力和顺时针扭矩显著小于300 rpm组,OTR运动产生更高逆时针扭矩;各组成形能力无显著差异。

要点

  • 500 rpm较300 rpm显著降低最大上抬力和顺时针扭矩。
  • OTR运动较连续旋转产生更高最大逆时针扭矩。
  • 各组成形能力(根管体积变化、中心定位比)无显著差异。

核心结论

  • 在JIZAI器械离体牙实验中,500 rpm较300 rpm产生显著更低的最大旋入力和扭矩值。
  • 连续旋转与OTR运动在根管成形方面表现相似。

研究设计与样本

  • 离体下颌磨牙近中根管经micro-CT扫描解剖匹配后,使用JIZAI器械预备至25号0.04锥度。
  • 分为连续旋转或OTR运动,各再分300或500 rpm组,每组n=10。
  • 使用自动根管预备与扭矩/力分析装置模拟啄式运动并实时记录扭矩和力。

主要发现

  • 500 rpm组最大上抬力和顺时针扭矩显著小于300 rpm组(P < .05)。
  • 连续旋转与OTR运动之间最大上抬力和顺时针扭矩无显著差异(P > .05)。
  • OTR运动最大逆时针扭矩显著高于连续旋转(P < .05)。
  • 最大下压力量、根管体积变化及距根尖孔1、3、5、7 mm处中心定位比各组间无显著差异(P > .05)。
  • 所有组均无器械折断。

临床怎么用

  • 在实验室条件下,选用500 rpm可能降低JIZAI器械的旋入力和扭矩。
  • 连续旋转与OTR运动对根管成形效果相近,可根据临床需要选择。

局限性

  • 研究为离体牙实验室条件,临床适用性需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate how different rotational speeds affect the torque/force generation and shaping ability of rotary root canal instrumentation using JIZAI (MANI, Utsunomiya, Japan) nickel-titanium instruments in continuous rotation and optimum torque reverse (OTR) motion. METHODOLOGY: Mesial root canals of extracted mandibular molars were instrumented up to size 25, 0.04 taper using JIZAI instruments, and anatomically matched canals were selected based on geometric features of the canal [canal volume (mm3 ), surface area (mm2 ), length, 15°-20° curvature and radius of curvature (4-8 mm)] after micro-computed tomographic scanning. An automated root canal instrumentation and torque/force analysing device was programmed to permit a simulated pecking motion (2 s downward and 1 s upward at 50 mm min-1 ). The selected canals were prepared with size 25, 0.06 taper JIZAI instruments using continuous rotation or OTR motion and further subdivided according to the rotational speed (300 or 500 rpm, n = 10 each). Real-time clockwise/counterclockwise torque and downward/upward force were recorded using a custom-made torque/force analysing device. Then, the registered pre- and post-operative micro-computed tomographic datasets were examined to evaluate the canal volume changes and centring ratios at 1, 3, 5 and 7 mm from the apical foramen. Data were analysed using two-way analysis of variance or the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction (α = 5%). RESULTS: Maximum upward force and clockwise torque were significantly smaller in 500 rpm groups than in 300 rpm groups (P < .05); however, no significant difference was found between continuous rotation and OTR motion (P > .05). OTR motion developed higher maximum counterclockwise torque than continuous rotation (P < .05). Maximum downward force, canal volume changes and centring ratios were not significantly different among all groups (P > .05). There was no file fracture in any of the groups. CONCLUSIONS: Under laboratory conditions using JIZAI instruments, a rotational speed of 500 rpm generated significantly lower maximum screw-in forces and torque values than rotational speed of 300 rpm. Continuous rotation and OTR motion performed similarly in shaping the canals.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Kyaw MS, Ebihara A, Kasuga Y, et al. Influence of rotational speed on torque/force generation and shaping ability during root canal instrumentation of extracted teeth with continuous rotation and optimum torque reverse motion. Int Endod J. 2021. PMID: 33527449. doi:10.1111/iej.13485

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。