微创开髓洞型保留牙本质未增强下颌磨牙抗折性
研究比较超保守(UltraAC)与传统(TradAC)开髓洞型下颌第一磨牙去除硬组织体积与抗折性的关系。TradAC去除硬组织更多,但两组抗折力无显著差异,去除体积与抗折力无相关性。
要点
- 超保守开髓相比传统开髓去除的牙体硬组织更少。
- 两组修复后下颌第一磨牙的抗折力无显著差异。
- 去除硬组织体积百分比与抗折力无显著相关性。
核心结论
- 传统开髓去除硬组织体积虽大于超保守开髓,但去除体积与修复后下颌第一磨牙抗折力无相关性,微创开髓未增加抗折性。
主要发现
- 术前两组牙髓腔空间和牙体硬组织体积无差异(P > 0.05)。
- 开髓后TradAC组全牙和牙冠去除硬组织体积均显著大于UltraAC组(P < 0.05)。
- TradAC组抗折力902.9 ± 347.8 N,UltraAC组948.7 ± 405.7 N,两组无显著差异(P = 0.975)。
- 全牙去除硬组织体积百分比与抗折力无相关性(P = 0.525,r = -0.084)。
- 牙冠去除硬组织体积百分比与抗折力无相关性(P = 0.152,r = -0.187)。
临床怎么用
- 下颌第一磨牙根管治疗时,超保守开髓可减少牙体硬组织去除,但不应以增强抗折性为主要预期。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To evaluate the correlation between the volume of dental hard tissues removed and the fracture resistance of mandibular molar teeth with ultraconservative (UltraAC) or traditional (TradAC) access cavity preparations. METHODOLOGY: Sixty recently extracted and intact mandibular first molars were scanned in a microcomputed tomographic (micro-CT) device, anatomically matched and assigned at random to 2 groups (n = 30), according to the access cavity type: UltraAC or TradAC. After access preparation, mesial and distal canals were prepared using Reciproc instruments and a new scan was taken. The volumes of pulp chamber and dental hard tissues in each specimen were measured before and after the experimental procedures, and the percentage volume reduction of hard tissues calculated for the entire tooth and for the crown separately. Teeth were then root filled, restored and subjected to fracture resistance tests in an universal testing machine. The force required to fracture was recorded in Newtons (N). The adherence of the variables to a Gaussian curve was verified using a Shapiro-Wilk test. Skewed data were analysed with nonparametric Wilcoxon signed rank or Spearman correlation tests, whilst the normally distributed data were analysed with a dependent samples Student t-test. Level of significance was set at 5%. RESULTS: Pre-operatively, no difference was observed between groups regarding the volume of pulp canal space or dental hard tissues (P > 0.05). After access preparation, volumes of the removed hard tissues from the entire tooth and from the crown were significantly greater in teeth prepared with TradAC than with UltraAC (P < 0.05). No significant difference was observed in the fracture resistance values between TradAC (902.9 ± 347.8 N) and UltraAC (948.7 ± 405.7 N) groups (P = 0.975). The Spearman test was unable to identify a correlation between fracture resistance and percentage volume of removed dental hard tissues in the entire root (P = 0.525, r = -0.084) or only in the crown (P = 0.152, r = -0.187). CONCLUSION: The volume of hard dental tissues removed, although greater in teeth with TradAC compared to UltraAC, did not correlate with the fracture resistance results, indicating that a minimally invasive access cavity did not increase the resistance of restored mandibular first molars to fracture.
引用
- Silva EJNL, Lima CO, Barbosa AFA, et al. Preserving dentine in minimally invasive access cavities does not strength fracture resistance of restored mandibular molars. Int Endod J. 2021. PMID: 33527413. doi:10.1111/iej.13487
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。