文献速递牙体牙髓病

加热对钙硅酸盐类根管封闭剂稳定性及理化性能的影响

Heating stability, physical and chemical analysis of calcium silicate-based endodontic sealers.
PubMed 文献 · Int Endod J · 2021-03-09

本研究用振动光谱和理化性能测试评估4种根管封闭剂在加热条件下的变化。钙硅酸盐类封闭剂受加热影响,溶解度高于ISO标准,仅AH Plus加热后稳定。

要点

  • 钙硅酸盐类根管封闭剂加热后流动性显著改变,溶解度超过ISO标准限值。
  • FT-IR显示EndoSequence BC Sealer HiFlow和Bio-C Sealer加热后吸水谱变化,可能与脱水有关。
  • AH Plus是唯一加热后化学稳定的根管封闭剂。

核心结论

  • 所测试的钙硅酸盐类根管封闭剂受加热影响,且溶解度较高,临床使用需关注。
  • AH Plus是唯一加热后稳定的根管封闭剂。

研究设计与样本

  • 体外研究评估EndoSequence BC Sealer HiFlow、Bio-C Sealer、BioRoot RCS和AH Plus四种根管封闭剂。
  • 采用拉曼光谱(25-220°C)和FT-IR(37-100°C)分析化学变化,并按ISO 6876-2012和ASTM-C266-07评估流动性、凝结时间、溶解度和阻射性。

主要发现

  • 振动光谱显示硅酸三钙、硅酸二钙和二氧化锆峰,加热时拉曼谱化学变化轻微。
  • FT-IR显示EndoSequence BC Sealer HiFlow和Bio-C Sealer加热后吸水谱变化,Bio-C Sealer在100°C后出现聚乙二醇谱带。
  • 加热至100°C显著改变所有钙硅酸盐类封闭剂的流动性,凝结时间变异大,溶解度超过ISO标准。
  • 所有封闭剂阻射性符合要求,pH呈碱性。

关键数值与推荐

  • 加热至100°C显著改变所有钙硅酸盐类封闭剂的流动性。
  • 钙硅酸盐类封闭剂溶解度水平超过ISO标准。
  • 所有测试封闭剂阻射性满足要求,pH呈碱性。

临床怎么用

  • 临床加热使用钙硅酸盐类根管封闭剂时需注意其流动性和溶解度变化。
  • AH Plus加热后化学稳定,可作为需加热条件下的选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To evaluate possible modifications in root canal sealers subjected to a variety of heating conditions using vibrational spectroscopy and analysis of physical and chemical properties. METHODOLOGY: EndoSequence BC Sealer HiFlow, Bio-C Sealer, BioRoot RCS and AH Plus were analysed chemically using Raman spectroscopy (25-220 °C) and Fourier-transform infrared spectroscopy (FT-IR) (37-100 °C ). For FT-IR, the materials were tested individually and mixed with root dentine powder. Scanning electron microscopy (SEM) and coupled energy dispersive spectroscopy (EDS) were used to evaluate surface and chemical elements. ISO 6876-2012 and ASTM-C266-07 specifications were followed to evaluate flow, setting time (moist and dry), solubility and radiopacity. Also, pH analysis at 37 and 100 °C was performed. Shapiro-Wilk and Mixed ANOVA (within and between the effects of the subjects), Levene, and a post hoc analyses with Bonferroni correction were performed (P < 0.05). RESULTS: Vibrational spectroscopy revealed peaks of tricalcium silicate, dicalcium silicate and zirconium dioxide. Chemical changes in the Raman spectra during heating were discrete, as the inorganic content predominated the signalling for all root canal sealers. FT-IR analysis exhibited spectral changes in water absorption for EndoSequence BC Sealer HiFlow and Bio-C Sealer, probably related to dehydration. For BioRoot RCS and AH Plus, no significant chemical changes were observed. Bio-C Sealer exhibited a band of polyethylene glycol only after heating to 100 °C, probably related to its thermal decomposition. SEM/EDS analysis corroborated the composition results observed in vibrational spectroscopy for all materials. Heating to 100 °C significantly changed the flowability of all calcium silicate-based sealers with a wide variation in setting times at both temperatures, along with solubility levels above ISO standards. For all tested sealers, radiopacity fulfilled the requirements, and pH exhibited alkaline values. CONCLUSIONS: The tested calcium silicate-based sealers were affected by heating. Calcium silicate-based root canal sealers had high solubility which is a concern for their clinical use. AH Plus was the only root canal sealer that was stable after heating.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Antunes TBM, Janini ACP, Pelepenko LE, et al. Heating stability, physical and chemical analysis of calcium silicate-based endodontic sealers. Int Endod J. 2021. PMID: 33577106. doi:10.1111/iej.13496

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。