文献速递口腔修复与种植

单颗与双颗种植体下颌覆盖义齿:亲水表面钛锆种植体早期负载的1年随机临床试验

Single versus two-implant mandibular overdentures using early-loaded titanium-zirconium implants with hydrophilic surface and ball attachments: 1-year randomized clinical trial.
PubMed 文献 · Clin Oral Implants Res · 2021-01-24

结果显示两组在患者满意度、口腔健康相关生活质量及咀嚼功能方面均显著改善,且1-IOD组咀嚼功能不劣于2-IOD组,支持两种方案均可用于无牙下颌治疗。

要点

  • 单颗与双颗种植体下颌覆盖义齿在1年内患者报告结局无显著差异。
  • 1-IOD组咀嚼功能不劣于2-IOD组(基于15%非劣效界值)。
  • 两组患者满意度和OHIP-Edent评分均较基线显著改善并维持至1年。

核心结论

  • 结果支持单颗和双颗种植体下颌覆盖义齿均可使用。
  • 单颗种植体覆盖义齿可作为无牙下颌治疗的次要可接受替代方案。

研究设计与样本

  • 所有患者接受新全口义齿,并植入亲水表面钛锆种植体(1-IOD为中线单颗,2-IOD为双侧尖牙区各一颗),早期负载,球帽附着体固位。
  • 随访6个月和12个月,评估患者满意度、口腔健康相关生活质量和咀嚼功能,采用广义估计方程分析,检验优效性和非劣效性假设。

主要发现

  • 与基线相比,插入新义齿后及1年随访时OHIP-Edent评分显著改善。
  • 1-IOD组与2-IOD组在OHIP-Edent和QoLFAST评分上无差异。
  • 患者对下颌义齿的满意度从基线到6个月随访显著提高,并维持至1年,组间无差异。
  • 患者报告结局的效应量大小为中等至大。
  • 两组咀嚼功能均呈渐进性改善。

关键数值与推荐

  • 基于15%非劣效界值的非劣效性检验:患者报告结局结果不确定,而1-IOD组咀嚼功能被判定不劣于2-IOD组。

临床怎么用

  • 单颗种植体覆盖义齿可作为双颗种植体方案之外的可接受替代选择。
  • 使用亲水表面钛锆种植体早期负载并采用球帽附着体可获得良好的短期患者报告结局。

局限性

  • 随访时间仅1年,为短期结果。
  • 非劣效性检验在患者报告结局上结果不确定,需谨慎解读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This randomized clinical trial aimed to compare the outcomes of the mandibular overdenture retained by one (1-IOD) or two (2-IOD) implants. MATERIALS AND METHODS: Participants received new complete dentures, were assessed at baseline and randomly assigned to groups. Early loaded single midline implant (1-IOD) or two implants in the canine regions bilaterally (2-IOD). Ball attachments were used for overdenture retention. Post-treatment outcomes (6- and 12-month follow-ups) included patient satisfaction, oral health-related quality of life measures, and chewing function. Data analysis included within- and between-group comparisons, and Generalized Estimating Equations. Both superiority and non-inferiority hypotheses were tested. RESULTS: Forty-seven participants were included (1-IOD = 23; 2-IOD = 24). Significant improvements in OHIP-Edent were observed after insertion of new dentures and at the 1-year follow-up compared with baseline. No differences were found between the 1- and 2-IOD groups for the OHIP-Edent and QoLFAST scores. Patient satisfaction with the mandibular denture improved significantly from baseline to the 6-month follow-up and remained unaltered until 1 year, with no differences between groups. The magnitudes of treatment effect sizes were moderate to large for patient-reported outcomes. Progressive improvement in chewing function occurred in both groups. Non-inferiority testing based on a 15% non-inferiority margin showed inconclusive results for patient-reported outcomes, whilst chewing function in the 1-IOD group was concluded to be not inferior to the 2-IOD group. CONCLUSIONS: Results support the use of both 1- and 2-IOD. The 1-IOD was also an acceptable alternative to the 2-IOD as a secondary option for the treatment of the edentulous mandible.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. de Resende GP, Jordão LMR, de Souza JAC, et al. Single versus two-implant mandibular overdentures using early-loaded titanium-zirconium implants with hydrophilic surface and ball attachments: 1-year randomized clinical trial. Clin Oral Implants Res. 2021. PMID: 33417279. doi:10.1111/clr.13707

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。