动态导航系统辅助根尖切除术在尸体模型中精度与效率优于徒手技术
AIM: To determine and compare the accuracy and efficiency of a dynamic navigation system (DNS) with a freehand (FH) technique when conducting root-end resection in a human cadaver model.…
要点
- DNS辅助根尖切除术的线性偏差、角度偏斜和操作时间均显著小于徒手技术。
- 根尖距颊侧骨板超过5 mm时徒手技术精度下降、操作时间延长且失误增多。
- DNS组与FH组在失误数量上无显著差异。
核心结论
- 在尸体模型中,动态导航系统进行根尖切除术比徒手技术更精确、更高效。
- 根尖距颊侧骨板距离对徒手技术的精度和效率有显著负面影响,对动态导航系统无此影响。
- 动态导航系统有潜力成为牙髓显微外科安全可靠的技术补充。
研究设计与样本
- 术前拍摄锥形束CT(CBCT),使用X-guide软件进行虚拟钻孔路径和深度规划。
- DNS组在导航下完成截骨和根尖切除术,FH组在牙科手术显微镜下徒手完成,术后拍摄CBCT。
- 比较线性偏差、角度偏斜、操作时间和失误数量,采用Shapiro-Wilk检验、单因素方差分析和Fisher精确检验(P < 0.05)。
主要发现
- DNS组的线性偏差、角度偏斜和操作时间均显著小于FH组(P < 0.05)。
- 两组失误数量无显著差异(P > 0.05)。
- 亚组分析显示,根尖距颊侧骨板超过5 mm时,FH组的精度显著降低、操作时间显著增加、失误发生率显著升高(P < 0.05),而DNS组无此显著关联。
临床怎么用
- 对于根尖距颊侧骨板较远(超过5 mm)的病例,动态导航系统可能提供更精确高效的根尖切除术。
- 动态导航系统可作为牙髓显微外科的辅助技术,但需结合临床条件评估。
局限性
- 研究为尸体模型研究,结果需在临床环境中进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To determine and compare the accuracy and efficiency of a dynamic navigation system (DNS) with a freehand (FH) technique when conducting root-end resection in a human cadaver model. METHODOLOGY: Forty roots in cadaver heads were included and divided into two groups: DNS (n = 20) and FH (n = 20). Cone beam computed tomography (CBCT) scans of all teeth were taken. The drilling path and depth were planned virtually to using the X-guide software (X-Nav Technologies, Lansdale, PA, USA). Osteotomy and root-end resection were done under navigation in the DNS group, and freehand under the dental operating microscope in the FH group. Post-operative CBCTs were taken. Linear deviations, angular deflection, time of operation and number of mishaps were compared with determine the accuracy and efficiency. Shapiro-Wilk, one-way ANOVA and Fisher exact tests were used (P < 0.05). RESULTS: Linear deviations, angular deflection and operation time were significantly less in the DNS group (P < 0.05). The number of mishaps was not different between the two groups (P > 0.05). Subgroup analyses revealed that the distance of >5 mm from buccal cortical plate was significantly associated with lower accuracy, increased operation time and greater incidence of mishaps in the FH group (P < 0.05), but not in the DNS group. CONCLUSIONS: The dynamic navigation system was more accurate and more efficient in root-end resection in a cadaver model than the freehand technique. The distance of the roots from the buccal cortical plate had a significant negative impact on the accuracy and efficacy of the root-end resection procedure when using the freehand technique. The dynamic navigation system has the potential to be a safe and reliable technological addition to endodontic microsurgery.
引用
- Dianat O, Nosrat A, Mostoufi B, et al. Accuracy and efficiency of guided root-end resection using a dynamic navigation system: a human cadaver study. Int Endod J. 2021. PMID: 33368371. doi:10.1111/iej.13466
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。