文献速递口腔修复与种植牙周病

牙周炎患者下颌后牙区不同表面种植体的边缘骨吸收:回顾性研究

Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study.
PubMed 文献 · Clin Oral Implants Res · 2021-01-01

本研究回顾性评估了268例有牙周炎病史并接受牙周支持治疗的患者在下颌后牙区植入的755枚外六角种植体的边缘骨吸收(CBL)。随访1-6年发现,阳极氧化表面种植体的CBL显著高于车削和混合表面种植体(6年时分别为1.92/1.46/1.02 mm,p < .01),且CBL≥2 mm的患病率在阳极氧化组更高。

要点

  • 牙周炎患者下颌后牙区阳极氧化种植体的边缘骨吸收显著高于车削和混合表面种植体。
  • 6年时CBL≥2 mm的患病率在阳极氧化组为40%,混合和车削组为15.6%。
  • 6枚阳极氧化种植体在4-5年间因故移除。

核心结论

  • 在有牙周炎病史并接受支持治疗的患者下颌后牙区,阳极氧化种植体的边缘骨吸收显著高于混合和车削种植体,随访1-6年。

研究设计与样本

  • 回顾性研究,纳入2007-2015年间268例连续患者,共植入755枚外六角种植体(72枚车削、145枚混合、538枚阳极氧化),随访1-6年,通过校准数字根尖片每年评估边缘骨吸收。

主要发现

  • 6年时(53例患者)平均CBL在患者/种植体水平分别为1.34/1.42 mm(范围0-5.2 mm)。
  • 阳极氧化种植体的CBL显著高于车削和混合种植体(1.92/1.46/1.02 mm,p < .01)。
  • CBL≥2 mm的种植体在3年时为18%,6年时为35%(p < 2.2 × 10-16);阳极氧化组患病率是混合和车削组的2.6倍(40%/15.6%,p < .0094)。
  • 6年时25枚阳极氧化种植体(18%)出现CBL≥3 mm。
  • 4-5年间共移除6枚阳极氧化种植体(涉及5例患者)。

临床怎么用

  • 对于有牙周炎病史的患者,在下颌后牙区选择种植体表面时,应优先考虑混合或车削表面而非阳极氧化表面,以降低边缘骨吸收风险。

局限性

  • 本研究为回顾性设计,随访年限1-6年不等,6年时仅53例患者,可能存在选择偏倚和信息偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To retrospectively assess the interproximal bone loss (CBL) in external hexagon implants (EHI), with different surface micro-topography, placed in the posterior mandible in patients with a history of periodontitis undergoing supportive periodontal care. MATERIAL AND METHODS: 268 consecutive patients received 755 EHI implants in the mandibular molar region between 2007 and 2015 with the following surface characteristics: 72 turned, 145 hybrids (double acid-etched/turned), and 538 anodized. CBL was yearly evaluated by analysing calibrated digital periapical radiographs, with a follow-up of 1-6 years. Data on implant survival were also calculated. RESULTS: At 6 years (53 patients), the mean CBL was 1.34/1.42 mm at patient/implant level, respectively (range: 0-5.2 mm). Significantly higher CBL was detected in anodized implants than in turned and hybrid implants (1.92/1.46/1.02 mm) (p < .01). The maximum CBL values were found in 2 anodized implants at 4 years (6.3 and 8.1 mm). CBL ≥2 mm was detected in 18% of implants at 3 years and 35% at 6 (p < 2.2 × 10-16 ), this prevalence being 2.6 times higher in the anodized than in the hybrid and turned group (40%/15.6%, p < .0094). At 6 years, 25 anodized implants presented CBL ≥3 mm (18%). 6 anodized implants (5 patients) were removed between 4 and 5 years. CONCLUSION: A significant higher CBL was observed in anodized, compared to hybrid and turned implants, when placed in the mandibular molar region of periodontal patients, with a follow-up of 1 to 6 years.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Sicilia A, Gallego L, Sicilia P, et al. Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study. Clin Oral Implants Res. 2021. PMID: 33210774. doi:10.1111/clr.13682

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。